Empty solvent tank – MAHLE RTI ACF-3000 User Manual
Page 7

Empty Solvent Tank
The flush solvent can only be used to flush one vehicle A/C system. Remove used
flush solvent from the ACF-3000 as follows:
IMMEDIATELY remove solvent after every system flush. Leaving solvent in
machine will saturate the charcoal filter.
1. Turn the Control Valve to OFF.
2. Attach the drain extension hose on the
“IN” (or output) Hose and place it into a
waste container.
3. Turn the Selector Valve to PURGE.
4. Turn the Control Valve to FLUSH.
5. Verify that the ACF-3000 is completely
drained before continuing.
6. Open charcoal air filter drain until all
moisture is drained and close valve.
7. Turn the Control Valve to OFF.
8. At this point the Spin-on Filter needs to be removed and replaced (Refer to the next
page).
*Follow your local state, municipal or federal waste management authority or
recycler to dispose the used flushing solvent and filters.
6
INPUT LINE
OUTPUT LINE