Recover/recycle – MAHLE RTI TC670V User Manual

Page 11

Advertising
background image

RTI Technologies, Inc.

February 5, 1996

Page 8

Figure 2 Recover/Recycle

RECOVER/RECYCLE

To Recover/Recycle, refer to Figure 2 and follow these steps:

1.

Attach Red and Blue Hoses to the A/C system per the vehicle manufacturer's instructions.

Note For R134a Machines

Field Service Couplings on the ends of Service Hoses are of a special design.

The valves have LEFT HAND threads which makes operation opposite to that of others.

To Close...

Turn Counter-clockwise

To Open...

Turn Clockwise

The valves MUST BE CLOSED before connecting or disconnecting Field Service Couplings.

2.

Open High and Low Gauge Valves.

3.

Open Red and Blue Hose Valves.

4.

Press top (ON) of rocker switch marked RECOVER/RECYCLE.