Vcx- 4, Top off, Flush radiator – MAHLE RTI VCX-4 User Manual

Page 11: Page 10

Advertising
background image

Page 10

AFTER EVERY PROCEDURE

TURN ALL VALVES TO HOME

HOME

FILL NEW TANK

EMPTY NEW TANK

EMPTY WASTE TANK

EMPTY WASTE TANK

(PRESSURE)

TOP OFF

EMPTY NEW TANK

EMPTY RADIATOR

(VACUUM)

EMPTY RADIATOR

FILL NEW TANK

TOP OFF

EMPTY NEW TANK

FILL RADIATOR

FILL NEW TANK

HOME

TOP OFF

VACUUM GAUGE

HOME

ON

HOME

HOME

ON

HOME

ON

NEW 2

NEW 1

NEW 3

SELECT NEW COOLANT SOURCE

TURN ONE VALVE ON TO

VCX- 4

Top Off

1.

Turn all panel valves to the Home position.

2.

Connect shop air to VCX Shop Air
Coupler.

3.

Turn the Cone Adapter Valve to the
closed position.

4.

Turn the appropriate New Tank Valve to
fill from the corresponding tank. Note
that New Tank 1 is used in the
illustration shown.

5.

Turn all panel valves to the Top Off
position as shown in the illustration. This
orientation can also be obtained by
positioning the panel valves toward the
blue highlights closest to each valve.

6.

Open the Cone Adapter Valve to fill the
radiator and overflow to the proper
levels.

7.

Turn all valves to the Home position.

8.

Close the Cone Adapter valve when
done.

9.

Replace radiator and overflow caps.

Flush Radiator

1.

The New Coolant Tank needs to be filled with water. See Empty Waste Tank and Fill New Tank
procedures.

2.

The Empty Radiator function must be run to completion.

3.

Run the Fill Radiator procedure.

4.

The Empty Radiator function must be run again to extract all of the water inside the cooling system.

5.

Repeat steps 3 and 4 until the desired results are achieved. Once completed new coolant needs to
be added to the vehicle system.

Advertising