6 TECHNICAL
SPECIFICATION
Electrical
Volts/Ph/Frequency
230/1/50
Power consumed
500 Watts
Full load current
2.2 Amps
Rating
Continuous
Max. No Starts per hour
60
Enclosure
IPX4
Fuse Size
5 Amps
Mechanical
Max flow
12 litres/min
Max head (closed valve)
32 metres
Max working pressure *
600 kPa (6 bar)
Max liquid temperature
35
o
C
Min liquid temperature
4
o
C
Max ambient air temperature
40
o
C
Max noise level
65 dB
P
ump
Dimensions
Length
210 mm
Width
130 mm
Height 231
mm
Weight
5.2 Kg
Connections
Inlet / outlet
G ¾ Male
Connecting cable
1.5 metres
Materials
Body
Brass
Shaft
Stainless Steel
Mechanical Seal
Nitrile/carbon/ceramic
Pump Parts
Brass
*Max working pressure is the maximum pressure that can be applied to the pump
internal casing under any installation condition.
Stuart Turner reserve the right to amend the specification in line with its policy of
continuous development of its products.