- 7 -

2.19

Pipework Connections:

Isolating valves: Always install isolating valves (not supplied) to

both suction and delivery pipe to aid future maintenance.

Pipework: Ensure pipework to and from the pump is independently

supported to prevent forces being transferred to the inlet and outlet
branches of the pump.

a) This pump must be installed in accordance with the Water Supply (Water

Fittings)

Regulations.

Incoming mains pressure can vary, but must never exceed 6 bar. If there is

a possibility of exceeding 6 bar, separate inlet pressure control must be fitted.

b) It is advisable to fit a bypass pipe and isolating valves. This will allow removal

of the pump for maintenance and servicing, and ensure the water supply into

the property is still available during that period (Fig. 3).

Fig. 3

Fig. 2

Typical installation

Mains water
stop cock

Inlet (see note ‘a’ above)

Mains
water
supply

Bypass (see note ‘b’ below)

(Not supplied)