- 15 -

Cont ...

5. Starting

The

Pump

a) Ensure all outlets are closed, turn power supply ‘on’ - pump will start, pressurise

the system then stop.

b) Open and close all outlets in turn associated with the pump, allowing liquid to

flow from each outlet until all air is purged. As each outlet is opened and closed,

the pump will start and stop respectively.

Note: After closing the outlet there will be a small time delay before the pump

stops, which is normal.

c) Any tap or control valve within the system when opened and closed will now turn

the pump on/off. Providing this is the case the system is now operating correctly.

d) Carefully check pump and pipework for leaks whilst pump running and stationary

before leaving the installation unattended.

For Further Technical Support

Phone the Stuart Turner PumpAssist team on 0844 98 000 97. Our staff are trained to

help and advise you over the phone or arrange for a service engineer to call.

Note: When pumps are installed in another manufacturers original equipment, please

contact the manufacturer for advice.

MAINTENANCE

WARNINGS:

Care should be taken to protect pump from frost and freezing.

If possible site the pump in a location where in the unlikely event of a

liquid leak, any spillage is contained or routed to avoid electrics or

areas sensitive to liquid damage.

Cleaners, disinfectants and descalents

On installations where chemical disinfectants or descalents are periodically

used, the compatibility of the chemical solution regarding the pump must be
considered.

Acid based descalents and aggressive cleaning agents must not come into

contact with the pump. The pump must be removed from the system prior to the
use of these products. The system should be flushed to remove all chemicals
before the pump is re-connected.

If in any doubt as to the suitability of the chemical solutions refer to Stuart

Turner Ltd.

1. No routine maintenance is required, but provision should be made

for easy access to the pump to allow repairs due to normal wear

and

tear.

2. Disconnect electrical supply before working on pump.

3. Turn off liquid supplies to the pump and release pressure by opening liquid outlets

before attempting maintenance.

4. Inlet strainers and footvalve strainers when fitted may require periodical cleaning.

The frequency of this operation is dependent upon installation conditions.