Examples

The following example specifies two trunks on a backbone device that connect to a peripheral device in
a substack. The first trunk contains ports 1 and 2; the second trunk contains ports 7 and 8. In both
cases, the first port in the trunk is an odd-numbered port.

Brocade(config-unit-1)# peri-trunk 1/3/1 to 1/3/2

Brocade(config-unit-1)# peri-trunk 1/3/7 to 1/3/8

History

Release

Command History

08.0.00a

This command was introduced.

show chassis

Displays chassis information for each stack unit.

Syntax

show chassis

Command Output

The show chassis command output displays the following information.

Output field

Description

Power supply #

The presence, status, output type, model number, serial
number, and firmware version number of the power
supply units, if present.

Power supply # Fan Air Flow Direction

The air flow direction of the power supply unit.

Fan #

The presence, status, speed mode, and air flow direction
of the fan. The fan controlled temperature and
temperature thresholds.

MAC # Temperature Readings

The current temperature reading of the MAC device.

CPU Temperature Readings

The current temperature reading of the CPU.

sensor # Temperature Readings

The current temperature reading of the sensor.

Boot Prom MAC

The MAC address of the boot prom

Management MAC

The management MAC address, for the active controller
only.

Modes

Privileged EXEC mode

show chassis