The following is the sample output from the show chassis command executed on an ICX 6610 device.

Brocade# show chassis

The stack unit 1 chassis info:

Power supply 1 not present

Power supply 2 (AC - Regular) present, status ok

Model Number: 23-0000143-01

Serial Number: F00E

Firmware Ver: 0

Power supply 2 Fan Air Flow Direction: Back to Front

Fan 1 ok, speed (auto): [[1]]<->2

Fan 2 not present

Fan controlled temperature: 64.0 deg-C

Fan speed switching temperature thresholds:

Speed 1: NM<----->82 deg-C

Speed 2: 77<-----> 86 deg-C (shutdown)

Fan 1 Air Flow Direction:Back to Front

MAC 1 Temperature Readings:

Current temperature : 47.5 deg-C

CPU Temperature Readings:

Current temperature : 64.0 deg-C

sensor A Temperature Readings:

Current temperature : 45.5 deg-C

sensor B Temperature Readings:

Current temperature : 48.0 deg-C

sensor C Temperature Readings:

Current temperature : 35.5 deg-C

stacking card Temperature Readings:

Current temperature : 60.5 deg-C

Warning level.......: 70.0 deg-C

Shutdown level......: 86.0 deg-C

Boot Prom MAC : 0000.0034.289c

NOTE
The output of the show chassis command is different for ICX 6610 devices and FastIron SX devices.

History

Release

Command History

08.0.00a

This command was enhanced to display model number,
serial number, and firmware version number for power
supply units.

show hardware mac-entry

Displays the hardware MAC address entries with an option to display the MAC address and the VLAN
ID for a specific device.

Syntax

show hardware mac-entry [ device device_id mac_address vlan_id ]

Parameters

device

device_id

Specifies the hardware device number.

mac_address

Specifies a MAC address to be displayed.

vlan_id

show hardware mac-entry