Mixed stack example

In this example, ICX 6450 peripheral devices are removed from a mixed stack. The mixed stack
contains two ICX 6610 devices in a ring configuration in the backbone. There are two substacks of three
ICX 6450 devices each in the mixed stack.

The following show stack output shows the configuration of the mixed stack before the stack
unconfigure mixed-stack command is executed. The show stack command is executed on the active
controller.

Brocade(config)# show stack

alone: standalone, D: dynamic config, S: static config

ID Typ Role Mac Address Pri State Comment

1 S FCX624 active 0012.f2eb.a900 128 local Ready

2 S FCX648 standby 00f0.424f.4243 0 remote Ready

3 S FCX624 member 00e0.5201.0100 0 remote Ready

Brocade# stack unconfigure 2

Will recover pre-stacking startup config of this unit, and reset it. Are you sure?

(enter 'y' or 'n'): y

Stack 2 deletes stack bootup flash and recover startup-config.txt from .old

Brocade# show stack

alone: standalone, D: dynamic config, S: static config

ID Type Role Mac Address Pri State Comment

1 S FCX624 active 0012.f2eb.a900 128 local Ready

2 S FCX648 member 0000.0000.0000 0 reserved

3 S FCX624 standby 00e0.5201.0100 0 remote Ready

active standby

+---+ +---+

=2/6| 1 |2/1==2/6| 2 |2/1=

| +---+ +---+ |

| |

|------------------------|

active standby

--- +---+ +---+ +---+ ---

( 1 )3/7--2/1| 6 |2/3==2/1| 7 |2/3==2/1| 8 |2/3==3/7( 2 )

--- +---+ +---+ +---+ ---

standby active

--- +---+ +---+ +---+ ---

( 2 )3/1==2/1| 5 |2/3==2/1| 4 |2/3==2/1| 3 |2/3--3/1( 1 )

--- +---+ +---+ +---+ ---

The following sequence shows the stack unconfigure mixed-stack command being executed on the
active controller. After confirmation, all peripheral ports and peripheral trunks are removed from the ICX
6610 devices. The peripheral ICX 6450 devices recover their configurations from before they were
members of the mixed stack, and they are reloaded.

Brocade# stack unconfigure mixed-stack

All the peri-ports/trunks will be removed and all the ICX6450 units will recover

pre-mixed-stacking configuration. Are you sure? (enter 'y' or 'n'): y

Removed peri-ports from configuration: 1/3/1 1/3/7

Removed peri-trunks from configuration: 2/3/1-to-2/3/2 2/3/7-to-2/3/8

The show stack command is executed on the active controller. The output shows that the ICX 6450
devices are no longer part of the mixed stack, because the MAC addresses are all zeroes, the State
column shows “reserve,” and the device status in the Comment column does not show “Ready.”

The Role column still shows “member” because the active controller retains the configuration of the
former stack member in reserve so that it can form a stack later if stack merge or stack formation
happens.

Brocade# show stack

alone: standalone, D: dynamic config, S: static config

ID Type Role Mac Address Pri State Comment

1 S ICX6610-24F active 748e.f891.c5b8 128 local Ready

2 S ICX6610-48P standby 748e.f834.4d14 0 remote Ready

Stacking Commands

FastIron Ethernet Switch Stacking Configuration Guide

155

53-1003090-02