Determining the status of a system fabric module, Figure 16, Switch fabr – Brocade VDX 8770-4 Hardware Reference Manual User Manual

Page 71: Table 12

Advertising
background image

Brocade VDX 8770-4 Hardware Reference Manual

51

53-1002563-04

Determining the status of a system fabric module

4

Determining the status of a system fabric module

At least one functional switch fabric module (SFM) must be plugged into slots S1 or S2 (the “control
plane slots”). If there are no functional SFMs in either slot during bootup, bootup is halted with a
message indicating that condition.

In an operational chassis, if all SFMs in the control plane slots become faulty or are removed, then
all the line cards will be faulted with a reason code that indicates no availability of an SFM. An
external RASlog message will also be displayed.

Complete the following steps to determine the status of an SFM.

1. Check the LED indicators on the SFM (refer to

Figure 16

). The LED patterns may temporarily

change during POST and other diagnostic tests. For information about how to interpret the LED
patterns, refer to

Table 12

.

2. You can use the show sfm command or the show slots command to see whether the SFM is

enabled.

Figure 16

identifies the switch fabric module.

FIGURE 16

Switch fabric module

Table 12

describes the switch fabric module LED patterns and the recommended actions for those

patterns.

1

Power LED

2

Status LED

TABLE 12

Switch fabric module LED descriptions

LED purpose

Color

Status

Recommended action

Power

No light (LED is off)

SFM is not on.

Ensure that the SFM is firmly seated
and the power switch is turned on
(slider is covering the captive
screw).

Steady green

SFM is on.

No action required.

2

1

Advertising