Sample 802.1x configurations
8
Hub configuration
illustrates a configuration where three 802.1x-enabled clients are connected to a hub,
which is connected to a port on the device. The configuration is similar to that in
, except
that 802.1x port security is enabled on only one port, and the multiple-hosts command is used to
allow multiple clients on the port.
FIGURE 8
Sample 802.1x configuration using a hub
The following commands configure the device in
.
Brocade(config)# aaa authentication dot1x default radius
Brocade(config)# radius-server host 192.168.9.22 auth-port 1812 acct-port 1813
default key mirabeau dot1x
Brocade(config)# dot1x-enable e 2/1
Brocade(config-dot1x)# re-authentication
Brocade(config-dot1x)# timeout re-authperiod 2000
Brocade(config-dot1x)# timeout quiet-period 30
Brocade(config-dot1x)# timeout tx-period 60
Brocade(config-dot1x)# max-req 6
Brocade(config-dot1x)# exit
Brocade(config)# interface e 2/1
Brocade(config-if-e100-1)# dot1x port-control auto
Brocade(config-if-e100-1)# exit
RADIUS Server
(Authentication Server)
NetIron Device
(Authenticator)
Clients/Supplicants running 802.1X-compliant client software
e2/1
192.168.9.22
Hub