Brocade Encryption Switch Hardware Reference Manual (Supporting Fabric OS v6.1.1_enc) User Manual

Page 41

Advertising
background image

Brocade Encryption Switch Hardware Reference Manual

27

53-1001117-02

3

Power supply
status

No light

Indicates one of the following:

•

Power supply FRU is switched
off.

•

Power supply FRU is not seated
correctly.

•

Power cord is disconnected.

•

Power cord is not actively
powered.

•

The power supply FRU has
failed.

Try the following:

•

Verify that the power supply FRU
is powered on.

•

Verify that the power supply FRU
is seated correctly.

•

Check the power cable
connection.

•

Replace the power supply FRU.

Steady green

Power supply is operating normally.

No action required.

Steady amber (for
more than 5
seconds)

Indicates one of the following:

•

Power supply FRU is switched
off.

•

Power supply FRU is not seated
correctly.

•

The power cable is
disconnected.

•

The power supply FRU has
failed.

Note: When the switch is first
powered on the power supply status
LED will show amber until POST has
completed.

Try the following:

•

Verify that the power supply FRU
is powered on.

•

Verify that the power supply FRU
is seated correctly.

•

Check the power cable
connection.

•

Replace the power supply FRU.

Fan status

No light

Indicates one of the following:

•

Fan FRU is not seated correctly.

•

Fan FRU is not receiving power.

Try the following:

•

Verify that the fan FRU is seated
correctly.

•

Verify that the switch is powered
on.

Steady green

Fan assembly is operating normally.

No action required.

Steady amber (for
more than 5
seconds)

Indicates one of the following:

•

Fan FRU is not seated correctly.

•

One or more of the fans in the
fan FRU has failed.

•

The fan FRU was disabled by
the user.

Note: When the switch is first
powered on the fan status LED will
show amber until POST has
completed.

Try the following:

•

Verify that the fan FRU is seated
correctly.

•

Verify that the fan FRU is
enabled (use the fanEnable
command).

•

Replace the fan FRU.

TABLE 2

Switch and FRU LEDs (Continued)

LED Name LED Color

Status of Hardware

Recommended Action

Advertising