Size and weight, Environmental requirements – Brocade Encryption Switch Hardware Reference Manual (Supporting Fabric OS v6.1.1_enc) User Manual
Page 47

Brocade Encryption Switch Hardware Reference Manual
33
53-1001117-02
A
Size and weight
lists the dimensions and weight of the switch.
Environmental requirements
lists the acceptable environmental ranges for operating and nonoperating (such as during
transportation or storage) conditions.
TABLE 3
Physical specifications
Dimension
Value
Height
2U = 86 mm (3.34 inches)
Depth
635 mm (25 inches)
Width
429 mm (16.88 inches)
Weight (with two power supplies; no SFPs)
22.4 kg (49.4 lbs)
TABLE 4
Environmental requirements
Condition
Acceptable During Operation
Acceptable During Non-Operation
Ambient
temperature
0
°
to 40
°
Celsius
(32
°
to 104
°
Fahrenheit)
-25
°
to 70
°
Celsius
(-13
°
to 158
°
Fahrenheit)
Humidity
10% to 85% RH non-condensing, at
40
° Celsius (104
°
Fahrenheit) , with maximum
gradient of 10% per hour
10% to 90% RH non-condensing, at 70°
Celsius (158
°
Fahrenheit)
Altitude
3,000 meters (9,842 feet) above sea level
0 to 12 kilometers (39,370 feet) above sea
level
Shock
20 G, 6 ms, half-sine wave
Half sine, 33 G 11ms, 3/eg Axis
Vibration
0.5 G sine, 0.4 grms random, 5-500 Hz
2.0 G sine, 1.1 grms random 5-500 Hz
Airflow
76 CFM (129/2 cubic meters per hour)
Maximum; 53 CFM (90.1 cubic meters per
hour) Nominal
N/A
Heat dissipation
1183 BTU/hr.
N/A