TROUBLE SHOOTING GUIDE CHECKLIST
NEVER MAKE ADJUSTMENTS TO ANY ELECTRICAL APPLIANCE OR PRODUCT WITH THE POWER
CONNECTED. DON’T JUST UNSCREW THE FUSE OR TRIP THE BREAKER, REMOVE THE POWER
FROM THE RECEPTACLE.
Blown fuse
Tripped breaker
Plug disconnected
Corroded plug
Low water level
Thermal overloaded
Defective motor
Jammed impeller
Blocked suction/inlet
Discharge leak
Blocked line/pipe
Worn impeller
Defective motor
Replace
Reset
Re-install
Clean prongs
Add water and verify
Unplug the pump for 15 minutes
than restart.
Replace/repair
Clean
Check for debris in pit and clean
Repair
Check for debris or ice
Repair/replace
Replace/ repair
TROUBLE PROBABLE CAUSE ACTION
Motor does
not run.
Pump does
not deliver
full capacity.