Effluent pump application, Repair parts, Step 2 – Burcam 300620 1/2HP 115V EFFLUENT PUMP MECHANICAL SWITCH User Manual
Page 5: Step 3, Step 4, Step 5, Step 6, Step 7, Step 8, Bur-cam pumps
![background image](/manuals/361770/5/background.png)
5
Repair parts may be ordered from your authorized point of sale or from
BUR-CAM PUMPS
EFFLUENT PUMP APPLICATION
STEP 2
Sump pit 18” diameter
X 25” depth
STEP 3
Prepare your choice
of discharge pipe size
and check valve
STEP 4
Install your pump in
centre of pit
STEP 5
Install discharge
pipe
STEP 6
Connect float and
motor power cable
STEP 7
Fill the basin and
test the operation
STEP 8
Review and check
connections for
leaks
REPAIR PARTS
1
2
3
4
5
12
18
15
11
14
16
7
13
8
17
9
10
6
19
REF PIECES
DESCRIPTION
1
350306
Base screws (9)
2
350297
Volute base
3
350528P Noryl impeller
3
350528
Brass impeller
4
350295
Volute cover
5
350277
Discharge reducer
6
350278
Mechanical seal
7
350125
Oil seal
8
350340
Lower bearing
9
350271
Rotor
REF PIECES
DESCRIPTION
10
350340 Upper bearing
11
350272 Stator
12
450532 Stator housing
13
350286.1 Bearing housing
14
350118.1 “O” ring
15
350273 Capacitor
16
350288 Upper casing
17
350289 Screw
18
350294
Power cable
19
450453
Mechanical switch