Trouble shooting guide checklist – Burcam 300526 1/2HP 115V EFFLUENT PUMP VERTICAL SWITCH C.I. /S. STEEL User Manual

Page 6

Advertising
background image

TROUBLE SHOOTING GUIDE CHECKLIST

NEVER MAKE ADJUSTMENTS TO ANY ELECTRICAL APPLIANCE OR PRODUCT WITH THE

POWER CONNECTED. DON’T JUST UNSCREW THE FUSE OR TRIP THE BREAKER, REMOVE

THE POWER FROM THE RECEPTACLE.

TROUBLE

PROBABLE CAUSE

ACTION

Switch is off position

Blown fuse

Tripped breaker

Plug disconnected

Corroded plug

Low water level

Thermal overcharge

Defective switch/float

Defective motor

Improper float position

Jammed impeller

Plugged check valve

Blocked suction/inlet

Discharge leak

Blocked line/pipe

Worn impeller

Defective motor

Defective switch

Float obstruction

Blocked suction/inlet

Turn switch to on position

Replace

Reset

Re-install

Clean prongs

Add water and verify

Cool the motor

Replace

Replace/repair

Check movement

Clean

Clean/replace

Check for debris in pit and clean

Repair

Check for debris or ice

Repair/replace

Replace

Replace

Adjust/check

Check for debris in pit and clean

Motor does not

run.

Pump does not

deliver to full

capacity.

Pump does not

shut off.

TO THE END CONSUMER

If you have any problems with the product, before advising the store, where you’ve

purchased the pump, please contact us at

514 337-4415, and ask for our sales

department, and they will be pleased to help you with any questions you might have,

concerning your installation.

Advertising