Sump pump application, Repair parts, Step 2 – Burcam 300527 SUBM SUMP PUMP S. STEEL 3/4HP 115V WITH 20FT CABLE User Manual

Page 5: Step 3, Step 4, Step 5, Step 7, Step 8, Step 6, Bur-cam pumps

Advertising
background image

5

Repair parts may be ordered from your authorized point of sale or from

BUR-CAM PUMPS

SUMP PUMP APPLICATION

STEP 2

Sump pit 18” diameter
X 25” depth

STEP 3

Prepare your choice
of discharge pipe size
and check valve

STEP 4

Install your pump in
centre of pit

STEP 5

Install discharge
pipe

STEP 7

Fill the basin and
test the operation

STEP 8

Review and check
connections for
leaks

REPAIR PARTS

STEP 6

Connect float and
motor power cable

1

3

2

4

7

8

6

9

10

5

300527 2008

#

Part

Description

1

310585

Nut and bolt for handle

2

310586

Handle

3

310587

Square support screw (2)

4

310588

Handle square support (2)

5

310589

Motor assembly

6

310590

Impeller

7

310591

Impeller lock nut

8

310592

Pump body screws (6)

9

310593

Gasket

10 310594

Pump boby

Advertising