Instruction steps – Burcam 300710 DE LUXE SUBM. SUMP PUMP VERTICAL SWITCH 1/2HP 115V User Manual

Page 3

Advertising
background image

APPLICATION

• This submersible sump pump is designed for a permanent

sump installation.

• For dewatering around homes and

farms. It can be used in light commercial

application.

300508P 300600P 300700P

CAPACITY:

300601 300610 300710

5’

2500

3000

3200

10’ 2100 2500 2850

15’ 1550 2000 2300

18’

550

1450

20’

1600

22’

1000

US GPH

FEATURES

• Non corrosive material.

• Stainless steel mechanical rotary seal.

• Thermal and overload protection.

• Piggy back grounded cables.

• 115VAC, 60Hz.

1/4 HP 3A, (7.5A when start)

1/3 HP 4A, (9.5A when start)

1/2 HP 5A, (12 A when start)

We recommend that you install your pump in a clean location where there is adequate

room for servicing at a later date. Protection from freezing temperatures and good

ventilation should be considered as well, to provide the pump an environment for long life.

Do not use to pump gas or toxic fuels. This submersible sump pump is designed

to pump water only.
Friction losses in the discharge pipe must be taken into consideration when the horizontal

offset is greater than 50 feet. The discharge pipe should be increased from 1 1/2” to 2”.

This will reduce friction losses and allow the pump to give maximum performance.
More friction losses must also be taken into consideration when many elbows and fittings

are installed in the discharge line. Each elbows and fittings must be considered as 1 feet

of head.
The float switch of your pump has been pre-set at the factory and does not need any

adjustment.
Never run the pump dry. Damage to the seal may occur. Fill pump pit or sump basin

with water before turning on the power.
Assuming that you have a sump pit located in your basement floor... Your sump pit must

be constructed from concrete, brick, tile or more recently a sump basin made from plastic

and/or fiberglass. The minimum size of your sump pit must be 18” in diameter and no less

than 25” deep. When pit is ready, proceed to next step.

STEP 1

STEP 2

FRICTION LOSS IN

PIPE NOT INCLUDED

INSTRUCTION STEPS

3

Please note before you proceed with the installation of this product that the manufacturer’s

guideline

has to be respected. Failure to comply may void your warranty.

The following are minimum requirements in order to protect your residence from flooding. It is a small investment but it is

your personal responsibility to protect your home, family and valuables. Failure to comply with the following requirements

may also void your warranty:
• Two (2) pumps

have to be installed in the sump pit. The first pump as a primary pump and the second pump as the

backup unit.

• Burcam alarm system model 450454

has to be installed to advise you of any malfunctions.

• As sump pumps are electrically powered and activated so to prevent flooding, a Burcam battery powered back up pump

model 300403

has to be installed to evacuate the water.

Pump selection, proper and adequate installation are a must to comply with local by-laws and need to be adhered to.

IMPORTANT NOTICE