2 printer (port one or port two), 3 duplex (port one only) – Condec DLR3110 User Manual

Page 37

Advertising
background image

Serial Input/Output

33

6.2

Printer (Port One or Port Two)

The selection of the PRINTER format is an on-demand serial data transmission that is initiated each time the
front panel

PRINT

key is pressed or when a remote print input is issued. This mode of serial data output is used

when interfacing to printers.

Figure 6-1. Printer Port One and/or Port Two Wiring

The data output format of the serial transmission is of the general form shown below:

<Pol><Data><space><Units><space><Mode><space><space><CR><LF>

Where:

<,>

=

Brackets are not sent in the transmission of the output data string.

Pol

= Single character field that defines polarity of data. Positive data would be space character

(20H) and negative data will have a “-” character (2DH).

Data

= Seven (7) digit numeric data field that includes decimal point and/or fixed dummy zero when

applicable. Leading zeroes are suppressed and an ASCII space character (20H) is
transmitted to hold the position of each leading zero.

space

=

Space character (20H)

Units

=

A character field that defines the current units of the display data (examples: PSI, cmH2O,
Kpa, mBAR, BAR, PASCAL).

Mode

=

An alpha character field that describes the current mode the indicator is in. GAGE/
ABSOLUTE/Delta P

CR

=

Carriage return

LF

=

Line feed

6.3

Duplex (Port One Only)

The selection of the DUPLEX format is only available on Port One. This selection sets up port 1 for bidirectional
communication in RS485, RS232, or 20mA. Because of the extensive list of command instructions that can be
issued to the indicator from a host computer, the scope of this section is limited to defining those commands that
are most often utilized. A more extensive document detailing the full operational parameters for serial duplex
protocol is available upon request from CONDEC. Ask for Duplex Serial Protocol Manual, PN 74845.

•

The duplex protocol includes the following basic functions:

d) Setup entry and recall

e) Current weight/pressure data recall

f) Calibration and correction recall and entry

g) All front panel key functions

h) Temperature calibration and correction recall and entry

TB2

S4

OUT

S5

IN

RETURN

I/O 1

I/O 2

(DIGITAL COMMON)

JUMPER PLUGS SHOWN ON S4 & S5 CONFIGURED AS AN INPUT

PRINT

PRINT

Advertising