Davey HS Series Electric Pumps User Manual

Hs series electric pumps, Priming and operation, Trouble shooting check list

Advertising
background image

Priming and Operation

1. Ensure outlet nearest to pump is

open.

2. Fill pump body and suction

line through priming plug hole
located above suction inlet and
replace plug.

Please pass these instructions on to the operator of this equipment.

Installation and

Operating Instructions

for Dynaflo

®

HS Series Electric Pumps

MODELS:

HS50-06, HS60-08

Trouble Shooting Check List

MOTOR OPERATING BUT NOT PUMPING
1. Suction line and pump body not filled with water.
2. Leaking foot valve.
3. Air leaks in suction lines or suction pipe not under water.
4. Air trapped in suction lines (also possible with flooded suction) due to

uneven rise in piping (eliminate humps and hollows).

5. No water at source or water level too low.
6. Valve on suction or delivery lines closed.

MOTOR NOT RUNNING
1. Power not connected.
2. Supply voltage too low.
3. Overload tripped.
4. Motor not free to turn e.g. a blocked impeller.
5. Internal motor fault.

MOTOR RUNS FOR SOME TIME THEN STOPS - RESTARTS
AUTOMATICALLY AFTER SHORT TIME
Overload tripping in motor - low voltage at motor terminals

- motor in direct sunshine or in “hot box”

- motor not free to turn (eg: blocked)

After Sales Service

For professional after sales service or repair contact your Davey Dealer.
For assistance in locating your nearest dealer contact the Davey Support
Centre on 1300 2 DAVEY.

3. Switch on.

4. Prime should establish almost

immediately with a strong flow
of water, however, in some
installations it may be
necessary to repeat
the above operation
to remove all air from
the system.

WARNING:

DO NOT RUN DRY.

DO NOT RUN WITH LOSS OF PRIME.

DO NOT PUMP WATER CONTAINING ABRASIVE MATERIALS.

*NOTE “MOTOR PROTECTION DEVICE” :

For protection, the Davey pump motor is fitted with an automatic

reset thermal overload, constant tripping of this overload indicates a

problem e.g. low voltage at pump, excessive temperature (above 50°C)

in pump enclosure.

WARNING: Automatic reset thermal overloads will allow the pump to

restart without warning. Always disconnect the pump motor from the

electrical supply before maintenance or repairs.

WARNING: When servicing or attending pump, always ensure power

is switched off and lead unplugged. Electrical connections should be

serviced only by qualified persons.

Care should also be taken when servicing or disassembling pump to

avoid possible injury from hot pressurised water. Unplug pump, relieve

pressure by opening a tap on the discharge side of the pump and allow

any hot water in the pump to cool before attempting to dismantle.

IMPORTANT:

DO NOT USE petroleum based fluids or solvents (e.g. Oils, Kerosene,

Turpentine, Thinners, etc) on the plastic pump components or seal

components.

Connection of Mains Scheme or Town Water Supply
to either Suction or Discharge of Pumps

Most Water Supply Authorities have strict regulations regarding direct
connection of pumps to mains water supplies. In most cases an isolating tank
is required between mains supply and pump. Davey also recommend this
method. Directly applied mains pressure can exceed pump operating pressure
and damage pump.

Davey Water Products Pty Ltd can not accept responsibility for loss or
damage resulting from incorrect or unauthorised installations.

Davey

®

Repair or Replacement Guarantee

In the unlikely event in Australia or New Zealand that this Davey pr

oduct develops any malfunction within two years of the date of original pur

chase due to

faulty materials or manufactur

e, Davey will at our option r

epair or r

eplace it for you fr

ee of char

ge, subject to the conditions below

.

Should you experience any difficulties with your Davey pr

oduct, we suggest in the first instance that you contact the Dav

ey Dealer fr

om which you

pur

chased the Davey pr

oduct. Alter

natively you can phone our Customer Service line on 1300 367 866 in Australia, or 0800 654 333 in New Zealand, or

send a written letter to Davey at the addr

ess listed below

. On r

eceipt of your claim, Davey will seek to r

esolve your difficulties or

, if the pr

oduct is faulty or

defective, advise you on how to have your Davey pr

oduct r

epair

ed, obtain a r

eplacement or a r

efund.

Your Davey T

wo Y

ear Guarantee naturally does not cover normal wear or tear

, r

eplacement of pr

oduct consumables (i.e. mechanical seals, bearings or

capacitors), loss or damage r

esulting fr

om misuse or negligent handling, impr

oper use for which the pr

oduct was not designed or advertised, failur

e to

pr

operly follow the pr

ovided installation and operating instructions, failur

e to carry out maintenance, corr

osive or abrasive water or other liquid, lightning

or high voltage spikes, or unauthorized persons attempting r

epairs. Wher

e applicable, your Davey pr

oduct must only be connected to the voltage shown

on the nameplate.

Your Davey T

wo Y

ear Guarantee does not cover fr

eight or any other costs incurr

ed in making a claim. Please r

etain your r

eceipt as pr

oof of pur

chase; you

MUST

pr

ovide evidence of the date of original pur

chase when claiming under the Davey T

wo Y

ear Guarantee.

Davey shall not be liable for any loss of pr

ofits or any consequential, indir

ect or special loss, damage or injury of any kind whatsoever ar

ising dir

ectly

or indir

ectly fr

om Davey pr

oducts. This limitation does not apply to any liability of Davey for failur

e to comply with a consumer guarantee applicable to

your Davey pr

oduct under the Australian or New Zealand legislation and does not af

fect any rights or r

emedies that may be available to you under the

Australian or New Zealand Consumer Legislation.

In Australia, you ar

e entitled to a r

eplacement or r

efund for a major failur

e and for compensation for any other r

easonably for

eseeable loss or damage. Y

ou

ar

e also entitled to have the goods r

epair

ed or r

eplaced if the goods fail to be of acceptable quality and the failur

e does not amount to a major failur

e.

Should your Davey pr

oduct r

equir

e r

epair or service after the guarantee period; contact your near

est Davey Dealer or phone the Davey Customer Service

Centr

e on the number listed below

.

For a complete list of Davey Dealers visit our website (davey

.com.au) or call:

*

Installation and operating instructions ar

e included with the pr

oduct when pur

chased new

.

They may also be found on our website.

P/N 402105

AUSTRALIA

Davey Support Centr

e

6 Lakeview Drive,

Scor

esby

, Australia 3179

Ph:

1300 367 866

Fax:

1300 369 119

W

ebsite:

davey

.com.au

Davey W

ater Pr

oducts Pty Ltd

Member of the GUD Gr

oup

ABN 18 066 327 517

NEW ZEALAND

Davey Support Centr

e

7 Rockridge A

venue,

Penr

ose, Auckland 1061

Ph:

0800 654 333

Fax:

09 527 7654

W

ebsite:

daveynz.co.nz

® Davey is a r

egister

ed trade mark of Davey W

ater Pr

oducts Pty Ltd.

© Davey W

ater Pr

oducts Pty Ltd 2012.

Advertising