Davey СxxxA/AB/TB CELSIOR SPA BATH PUMPS User Manual

Celsior hea t reco ver y, Pl umbers no te, Your davey spa bath pump

Advertising
background image

INST

ALLA

TION

AND OPERA

TION

MANU

AL

D

A

VEY

SP
A

B

A

TH
PUMP

C200A, C270A,

C400A

C200AB

,

C270AB

,

C400AB

C200TB

,

C270TB

,

C400TB

– 2 –

Your Davey Spa Bath Pump

Congratulations on your purchase of a quality product from the Davey

range of Pool and Spa Equipment. You are assured of many years of

reliable and efficient performance from your Davey Spa Bath Pump backed

by Davey’s two year guarantee.

The Davey Spa Bath Pump range has been specially designed to offer

optimum performance and ample bubbling pressure in spa baths. It should

not be used for any other purpose without first consulting your Davey

Dealer or Davey Customer Service Centre.

The AB and TB models incorporate a thermostatically controlled heater

element. The heater element maintains the bath water temperature for a

long hot bath.

The Celsior range is designed for use in spa baths. They are not

recommended for use in chemically treated spa pool water.

At Davey we design and build our own electric motors especially for our

pumps. The matched motor and “pumping end” are designed to provide

quiet operation while delivering optimum water flow.

Davey’s totally enclosed motor incorporates “auto-start” overload protection

with a built-in automatic thermostat designed to protect the motor from

overheating. The excess heat from the motor is captured by the spa water,

ensuring a long hot soak.

Davey Spa Bath Pumps are constructed of durable thermoplastic,

eliminating corrosion problems and consequent spa bath staining. Specially

designed to be self-draining (when installed as per instructions), the pump

drains after use, preventing the build-up of stale water.

Installation and Operating Instructions

Location

The pump should be located as close to the spa bath as practicable (either

internally or externally). It is the installer’s/owner’s responsibility to locate

the pump such that the nameplate can be easily read and it can be readily

accessed for service.

It is recommended that the pump is protected from the weather. Enclosures

should be ventilated to prevent condensation build–up.

Failure to adequately install the Spa Bath Pump as outlined above may

result in pump damage and/or removal costs not covered by the guarantee.

– 3 –

Electrical Connection

In the interests of safety, we advise that all Spa Bath Pumps must be

installed in accordance with relevant standards, particularly AS 3000 wiring

rules or equivalent.

This product is suitable for connection to a nominal 240V 50Hz power

supply and is equipped with a lead and three pin plug.

This product must be installed so the motor can be turned off independently

of the air button or touch pad (a standard ON/OFF power point provides

this).

If the supply cord of this product is damaged it must be replaced with a

genuine Davey Spare Part, by the manufacturer or its service agent or a

similar qualified person in order to avoid a hazard.

Air Switch Models - Tube Connection

These pumps are supplied with an air switch tube connected to the back of

the motor on the 200, 270 & 400.

1. Before installing, ensure that :

- the tube is properly connected to the pump,

- the tube can be connected to the air button (not supplied) at the bath.

2. When installing route the tube via the shortest possible path to the air

button. Ensure that there are no kinks.

3. Do not loop air tube around pipe work or framing.

Electronic Models -

Touchpad Assembly / Installation

These models are supplied with a low voltage electronic touch pad to

control pump and heater functions.

Assembly

Click faceplate onto touch pad. Then apply label to faceplate/touchpad

assembly ensuring it is right way up.

Installation

The assembled touchpad is then ready for mounting at the bath. Route

the lead to enable connection at both the touchpad and pump ends. A

26mm dia. hole is required to mount the touchpad flush on the bath surface

(usually pre drilled by bath manufacturer).

Apply a bead of silicone on the touchpad box only to secure it to the bath

surface and prevent water leaking under the bath. Do not silicone the clip

on faceplate to the bath surface.

IMPORT

ANT INST

ALLA

TION

INFORMA

TION

(Pump

must be able to

self drain)

Please pass these instructions on to the owner of this equipment.

PUMP

POSITION IS IMPORT

ANT

PL
UMBERS

NO
TE!

NOTE: To avoid possible water damage to property from ruptured

pipes, leaking connections, worn/leaking pump seals, etc., pumps

must be installed on a well drained site or in a properly construct-

ed drain tray.

CELSIOR

HEA

T

RECO

VER

Y

TM

Warning! Ensure that an electrical isolation switch is located

with easy access so that the pump can be switched off in an

emergency.

Davey

®

Repair or Replacement Guarantee

In the unlikely event in Australia or New Zealand that this Davey product develops any malfunction

within two years of the date of original purchase due to faulty materials or manufactur

e, Davey will at

our option repair or r

eplace it for you free of char

ge, subject to the conditions below.

Should you experience any difficulties with your Davey product, we suggest in the first instance that

you contact the Davey Dealer from which you pur

chased the Davey product. Alter

natively you can

phone our Customer Service line on 1300 367 866 in Australia, or 0800 654 333 in New Zealand, or

send a written letter to Davey at the address listed below

. On receipt of your claim, Davey will seek to

resolve your difficulties or

, if the product is faulty or defective, advise you on how to have your Davey

product r

epaired, obtain a r

eplacement or a refund.

Your Davey T

wo Year Guarantee naturally does not cover normal wear or tear

, replacement of pr

oduct

consumables (i.e. mechanical seals, bearings or capacitors), loss or damage resulting fr

om misuse

or negligent handling, improper use for which the pr

oduct was not designed or advertised, failure to

properly follow the pr

ovided installation and operating instructions, failure to carry out maintenance,

corrosive or abrasive water or other liquid, lightning or high voltage spikes, or unauthorized persons

attempting repairs. Wher

e applicable, your Davey product must only be connected to the voltage

shown on the nameplate.

Your Davey T

wo Year Guarantee does not cover fr

eight or any other costs incurred in making a claim.

Please retain your r

eceipt as proof of pur

chase; you

MUST pr

ovide evidence of the date of original

purchase when claiming under the Davey T

wo Year Guarantee.

Davey shall not be liable for any loss of profits or any consequential, indir

ect or special loss, damage

or injury of any kind whatsoever arising directly or indir

ectly from Davey pr

oducts. This limitation

does not apply to any liability of Davey for failure to comply with a consumer guarantee applicable to

your Davey product under the Australian or New Zealand legislation and does not af

fect any rights or

remedies that may be available to you under the Australian or New Zealand Consumer Legislation.

In Australia, you are entitled to a r

eplacement or refund for a major failur

e and for compensation for

any other reasonably for

eseeable loss or damage. You ar

e also entitled to have the goods repair

ed

or replaced if the goods fail to be of acceptable quality and the failur

e does not amount to a major

failure.

Should your Davey product r

equire r

epair or service after the guarantee period; contact your nearest

Davey Dealer or phone the Davey Customer Service Centre on the number listed below

.

For a complete list of Davey Dealers visit our website (davey.com.au) or call:

* Installation and operating instructions ar

e included with the product when pur

chased new.

They may also be found on our website.

P/N 49375-8 supersedes P/N 49375-7

AUSTRALIA

Customer Service Centre

6 Lakeview Drive,

Scoresby

, Australia 3179

Ph:

1300 367 866

Fax:

1300 369 119

Website:

davey

.com.au

Davey Water Pr

oducts Pty Ltd

Member of the GUD Group

ABN 18 066 327 517

NEW ZEALAND

Customer Service Centre

7 Rockridge Avenue,

Penrose, Auckland 1061

Ph:

0800 654 333

Fax:

09 527 7654

Website:

daveynz.co.nz

® Davey is a register

ed trade mark of Davey Water Pr

oducts Pty Ltd.

© Davey Water Pr

oducts Pty Ltd 2011.

Advertising