Davey PowerMaster 200, 250, 350, 450 (INCLUDING 415V 3 PHASE MODEL) User Manual

Location, Weather protection, Power connection

Advertising
background image

INSTALLA

TION AND OPERATING

INSTRUCTIONS

DA

VEY POWER MASTER

®

200, 250, 350, 450

(INCLUDING 415V 3 PHASE MODEL)

Please pass these instructions on to the owner of this equipment.

The installation of this product should be carried out by a person knowledgable

in swimming pool plumbing requirements following the Installation Instructions

provided in this manual.

– 2 –

Prior to using this pump you must ensure that:

• The pump is installed in a safe and dry environment

• The pump enclosure has adequate drainage in the event of leakage

• Any transport plugs are removed

• The pipe-work is correctly sealed and supported

• The pump is primed correctly

• The power supply is correctly connected

• All steps have been taken for safe operation

Appropriate details for all of these items are contained in the following Installation

and Operating Instructions. Read these in their entirety before switching on this

pump. If you are uncertain as to any of these Installation and Operating Instructions

please contact your Davey dealer or the appropriate Davey office as listed on the

back of this document.

Congratulations on your purchase of a quality product from the Davey range of

Pool and Spa Equipment. You are assured of many years of reliable and efficient

performance from your Davey Power Master

®

backed by Davey’s three year

guarantee.

Davey Power Masters

®

have been designed to circulate swimming pool and spa

water in conditions set out in the Australian Standard for swimming pool water quality

(AS 3633) or equivalent. They should not be used for any other purpose without first

consulting your Davey Dealer or the Davey Customer Service Centre.

Davey design and build its own electric motors especially for its pumps. The

matched motor and “pumping end” are designed to provide the quietest operation

while delivering maximum water flow.

Davey’s totally enclosed fan-cooled motor incorporates “autostart” overload

protection with a built-in automatic thermostat designed to protect the motor from

overheating.

Every Davey Power Master

®

is thoroughly water tested against a number of flow,

pressure, voltage, current and mechanical performance parameters. Davey`s

advanced pump manufacturing technology provides reliable and efficient pumping

performance that lasts and lasts.

Location

The pump should be located as close to the water as practicable and mounted on

a firm base in a well drained position, high enough to prevent any flooding. It is the

installer’s/owners responsibility to locate the pump such that the nameplate can be

easily read and it can readily accessed for service.

Weather Protection

It is recommended that the pump is protected from the weather. Enclosures should

be ventilated to prevent condensation build-up and allow a free flow of air for the fan

cooled motor.

Power Connection

Davey Power Masters

®

are suitable for connection to a nominal 240 (for 415 volt

refer to page 7) volt 50Hz power supply and are equipped with a flex and 3 pin plug.

If a power outlet is not available within 3 metres of the pump, a 3 pin power point in

a safe, dry place, may need to be provided by an electrician. Extension cords are

unsafe around pools - and should be avoided. If the supply cord of this product is

damaged it must be replaced by the dealer or manufacturer, with genuine Davey

spares.

– 3 –

Pipe Connection

A barrel union is provided for connecting to the piping from the pool.

The pumps are designed to accept the following PVC Pipes:

Model

Inlet PVC

Position

Outlet PVC

Position

PM200/250

40mm pipe

ID

40mm

ID

or 50mm fitting

OD

50mm fitting

OD

PM350

40mm pipe

ID

40mm pipe

ID

or 50mm fitting

OD

50mm fitting

OD

or 50mm pipe

ID

50mm pipe

ID

PM450

50mm pipe

ID

50mm pipe

ID

The use of any pipe smaller than those specified above is not recommended.

Suction piping should be free from all air leaks and any humps and hollows which

cause suction difficulties.

The discharge piping from the pump outlet should be connected to the inlet

connection on the swimming pool filter (usually at the filter control valve).

NOTE: Power Master

®

Pool Pumps are fitted with an internal check valve to

reduce reverse flow of water through the pump.

Warning! Ensure that an electrical isolation switch is located with easy

access so that the pump can be switched off in an emergency.

The fittings on this product are constructed of ABS. Some PVC jointing

compounds are incompatible with ABS. Check compound suitability

before use.

Children should be supervised to ensure that they do not play with the

appliance.

Davey Water Products recommends that all installations are fitted with

earth leakage or residual current protection devices.

CAUTION: In the interest of safety, we advise that all brands and types of

pool pumps must be installed in accordance with AS3000 wiring rules or

equivalent.

This appliance is not intended for use by persons (including children) with

reduced physical, sensory or mental capabilities, or lack of experience

and knowledge, unless they have been given supervision or instruction

concerning use of the appliance by a person responsible for their safety.

If the pump and filter are located below pool water level, it is necessary

to fit isolating valves in the pipe between the pump and the skimmer box

and in the return pipe from the filter to the pool.

Barrel unions need to be hand tightened. No sealant, glues or silicones are

required.

WARNING: Failure to follow these instructions and comply with all applicable

codes may cause serious bodily injury and/or property damage.

Davey

®

Repair or Replacement Guarantee

In the unlikely event in Australia or New Zealand that this Davey product develops any malfunction

within three years of the date of original pur

chase due to faulty materials or manufacture, Davey will

at our option repair or r

eplace it for you free of char

ge, subject to the conditions below.

Should you experience any difficulties with your Davey product, we suggest in the first instance that

you contact the Davey Dealer from which you pur

chased the Davey product. Alter

natively you can

phone our Customer Service line on 1300 367 866 in Australia, or 0800 654 333 in New Zealand, or

send a written letter to Davey at the address listed below

. On receipt of your claim, Davey will seek to

resolve your difficulties or

, if the product is faulty or defective, advise you on how to have your Davey

product r

epaired, obtain a r

eplacement or a refund.

Your Davey Thr

ee Year Guarantee naturally does not cover normal wear or tear

, replacement of

product consumables (i.e. mechanical seals, bearings or capacitors), loss or damage r

esulting

from misuse or negligent handling, impr

oper use for which the product was not designed or

advertised, failure to pr

operly follow the provided installation and operating instructions, failur

e to

carry out maintenance, corrosive or abrasive water or other liquid, lightning or high voltage spikes,

or unauthorized persons attempting repairs. Wher

e applicable, your Davey product must only be

connected to the voltage shown on the nameplate.

Your Davey Thr

ee Year Guarantee does not cover fr

eight or any other costs incurred in making a

claim. Please retain your r

eceipt as proof of pur

chase; you

MUST pr

ovide evidence of the date of

original purchase when claiming under the Davey Thr

ee Year Guarantee.

Davey shall not be liable for any loss of profits or any consequential, indir

ect or special loss, damage

or injury of any kind whatsoever arising directly or indir

ectly from Davey pr

oducts. This limitation

does not apply to any liability of Davey for failure to comply with a consumer guarantee applicable to

your Davey product under the Australian or New Zealand legislation and does not af

fect any rights or

remedies that may be available to you under the Australian or New Zealand Consumer Legislation.

In Australia, you are entitled to a r

eplacement or refund for a major failur

e and for compensation for

any other reasonably for

eseeable loss or damage. You ar

e also entitled to have the goods repair

ed

or replaced if the goods fail to be of acceptable quality and the failur

e does not amount to a major

failure.

Should your Davey product r

equire r

epair or service after the guarantee period; contact your nearest

Davey Dealer or phone the Davey Customer Service Centre on the number listed below

.

For a complete list of Davey Dealers visit our website (davey.com.au) or call:

* Installation and operating instructions ar

e included with the product when pur

chased new.

They may also be found on our website.

P/N 48717-10 supersedes P/N 48717-9

AUSTRALIA

Customer Service Centre

6 Lakeview Drive,

Scoresby

, Australia 3179

Ph:

1300 367 866

Fax:

1300 369 119

Website:

davey

.com.au

Davey Water Pr

oducts Pty Ltd

Member of the GUD Group

ABN 18 066 327 517

NEW ZEALAND

Customer Service Centre

7 Rockridge Avenue,

Penrose, Auckland 1061

Ph:

0800 654 333

Fax:

09 527 7654

Website:

daveynz.co.nz

® Davey & Power Master are r

egistered trade marks of Davey W

ater Products Pty Ltd.

© Davey Water Pr

oducts Pty Ltd 2011.

Advertising