Technical Data:

Model

MCU / LCU

Power (V)

220-240

Power Outlets

2

Outlet rating (A)

10A Total

Power Lead length (m)

1.9

Electrical Approval

NSW23093

IP

53

Dimensions:

(mm)

Height

Width

Depth

Mounting

Holes (Horiz)

Mounting

Holes

(Vert)

Mounting

Holes Diam

MCU

208

119

88

99

188

5

LCU

124

99

104

Installing the Master Control Unit (MCU):

1. When installing your MCU it is easier to program the network prior to mounting.

Simply plug in to any power outlet to activate the unit and begin programming.
Refer

to the section titled “Programming the MCU”.


2. Mount the MCU in a location that is greater than 3.5 meters from the pool zone

and less than 1.5 meters from a power supply socket. Make sure the unit is
within range of other units before mounting.


3. Plug the appliances to be controlled, into the outlets in the base of the MCU.

WARNING: The total current of the MCU must not exceed 10 Amp. The unit

must be installed in the upright position.

4. Plug the mains input lead into the power outlet 240V supply.

5. Switch on the power outlet and the 2 override switches on the MCU unit

(mechanical rocker switch above the outlets).