PREPARING YOUR SYSTEM

On removing your Steriflo

®

system from its carton you should check all

components, especially the lamp, to ensure all are present and have not
been damaged in transportation. you should have:
1. Power supply control box with indicator light(s) and electrical flex.
2. uV lamp (or lamps).
3. treatment chamber with mounting brackets.

Connect lead to power supply designated on control box label. Check that
the earth is connected to the stainless steel chambers using bolt provided
on the chamber.

Install the power supply enclosure above the treatment chamber so that in the
event of a leak, water cannot drip down the lamp lead into the enclosure.
CAUTION: The supply cord is necessary for lamp changing. The three pin
supply plug must remain accessible after installation. If installed to fixed
wiring without the plug a two pole switch must be fitted and its ON and OFF
positions shall be marked.

The appliance is not intended for use by young children or infirm persons

without supervision. Young children should be supervised to ensure they do

not play with the appliance

NOTE: The quartz sleeve has been factory fitted, and there is no need to

remove these endcaps on first installation. Before removing endcaps, please

read the Maintenance section of these instructions completely.

The Steriflo

®

control box has a red LED alarm indicator light mounted on

its front panel, adjacent to the amber “power on” LED. This light will be
illuminated whenever the Steriflo

®

control box senses no lamp current. There

is also an audible alarm in the event of lamp failure. The LED and/or alarm
will only work when unit is connected to the correct electrical supply.