Pump controllers torrium, Status indicator, Your new system incorporates ‘torrium – Davey Aquashield MAX Packaged Ultra Violet Water Treatment System User Manual

Page 7: The torrium

Advertising
background image

7

PUMP CONTROLLERS

TORRIUM

®

your new system incorporates ‘torrium

®

’, electronic flow controller – a

Davey designed unit that enables the use of a highly efficient pump design
and offers the following benefits:–
1. Enables the pump to deliver a constant flow of water particularly at

low flow rates – reducing the inconvenience of pressure variation in
showers etc.

2. Provides automatic “cut-out” protection should the pump run out of

water or overheat*, should the pump fail to start due to low voltage or a
blockage in the pump.

3. Provides warning indications for critical and noncritical system faults.
4. has adaptive pressure cut-in which allows the pump to start at

approximately 80% of the maximum pressure at last shut-down. This
allows the controller to accommodate varying inlet pressures and pump
performance.

5. automatic retry functions in the event of a critical system fault.
* Motor overload / overheat protection included. Motor has its own overload
/ overheat protection.

Status Indicator

the torrium

®

has a status indicator light on the front panel. this light will

enable you to understand what your pump is doing.

Condition

Indicator readout

Pump operation

Restart / Reset Method

standby mode

red light

standby

Pressure drop

Running

Green light

Running

N/A

Cistern fill

Yellow/Amber light

Running - 2 minutes

Auto, push “Prime” button or

minimum run time

cycle power off / on

Loss of Prime

Red light single flash

Stops, auto-retry &

Push “Prime” button or cycle

“water return” activated

power off / on

Locked rotor or ‘Prime’

Red light double flash

Stops

See Trouble shooting guide

button held in too long
Under voltage

Red light double flash

Normal operation

Wait till voltage >180 volts or

push “Prime” button or cycle

power off / on

Water over temperature

Red light triple flash

Stops

Wait till water temp < 60

o

c

Slow leak

Red light triple flash

Normal operation with

Auto-reset or push “Prime”

reduced cut-in pressure

button or cycle power off / on

The electrical connections and checks must be made by a qualified
electrician and comply with applicable local standards.

The Davey Torrium

®

fitted to this pump has a status indicator light mounted

on its front panel. This light will be illuminated whenever the Torrium

®

senses that there is electrical power available. The light will only work
when unit is connected to the correct electrical supply.

Advertising