Installation Addenda

39

Travis Industries

4 1 2 2 1 0 4

9 3 5 0 8 1 1 7

ADDENDUM #2 Interior Masonry Chimney Conversions

•

Follow the requirements and
use the equipment listed in
the illustration to the right to
install this appliance into an
interior masonry chimney.

•

Maximum vertical rise is 40'

•

Minimum vertical rise is 10'

•

See the chart on page 14 for
determining the correct
restrictor position.
NOTE: these restrictor
positions are based upon lab
tests. The ideal restrictor
position may vary slightly.

The entire chimney system

must be air-tight. Make sure to

seal the flashing, clean-out,

and thimble connection, and to

inspect the chimney.

#711 Flex Liner (4” dia.)

(or other UL 1777 Gas

Liner)

Co-Axial Straight

Lengths

#991 High Wind

Termination

#990 90° Elbow

Flashing (included in

#934 Masonry

Conversion Kit

Make sure the coaxial pipe

maintains a 1” clearance to any

combustible. The vent must be

sealed air-tight.

High-Temp.

Silicone

Connector with Cover

(included in #934 Masonry

Conversion Kit)

Interior Masonry Chimney

Standard Masonry Fireplace

Connector (included in #934

Masonry Conversion Kit)

secured and sealed to

block-off plate.

Flashing (included in

#934 Masonry

Conversion Kit)

#991 High Wind

Termination

#711 Flex Liner (4” dia.)

(or other UL 1777 Gas Liner)

The entire chimney system

must be air-tight. Seal the

connector cover and inspect

the chimney.

Make sure the coaxial pipe

maintains a 1” clearance to any

combustible. The vent must be

sealed air-tight.

High-Temp.

Silicone

Advertising