Alto-Shaam Combinaton Oven/Steamer CT Express 4.10ESiVH User Manual

Page 18

Advertising
background image

CT ExpRESS INSTALLATION MANUAL • 16 .

i n s t a l l a t i o n

w a t e r v a l v e

w a t e r d r a i n a g e

note:

the shut-oFF valve
must be in the oPen Position
when the oven is being used.

The oven must discharge through an indirect waste pipe by means of an air gap. The drain fitting is

supplied with a 1-1/2-inch (38mm) npT thread.

a union is required. install a 1-1/2-inch (38mm)

diameter connection, drain line and clamp into

place. The drain line must always be a positive

gradient away from the combitherm oven and not

more than 12-inches (305mm) before an air gap.

NOTE:

in the u.s.a., this equipment is to be

installed to comply with the Basic plumbing
code of the Building officials and code
administrators international, inc. [Boca],
and the Food service sanitation Manual of
the Food & drug administration [Fda].

if several units are to be connected to one drain

pipe, the dimensions of the pipe must be sufficient

to allow an unobstructed water drain system.

1-1/2" (38mm) diameter NPT

at back of oven

WASTE PIPE

1-1/2" to 2" minimum diameter

(c. 38mm to 51mm)

2" (51mm)

Air Gap

1-1/2" (38mm)

diameter connection

required for drain

Advertising
This manual is related to the following products: