CT ExpRESS INSTALLATION MANUAL • 18 .

i n s t a l l a t i o n

v e n t l e s s h o o d m o d e l

top exhaust vent

1

Charcoal Filter: The charcoal filter should be

inspected for contaminant's on a regular basis.

replacement must be made at a minimum of

three month intervals — more often if heavy

contaminant's are visible or if the filter no

longer controls odors.

To remove the charcoal filter, pull and slide out.

when replacing the filter, ensure that the filter

clip is in place at rear of the filter. Make certain

the air flow arrow(s) point toward the hood fan

(back of unit), and that the filter is replaced

using the filter track in the metal back plate

provided with the hood.

Fi-24114

2

Grease Filter: cleaning frequency should be

based on oven usage with a maximum of two

weeks between cleaning if the oven is used for

non-grease laden products or steam applications

only. grease laden products require cleaning

frequency of at least once a week.

remove the grease filter by pulling it straight

out of the housing. place the filter in the

dishwasher or wash separately by placing in

hot, soapy water until all grease and particles

have been removed. rinse thoroughly. allow

the filter to air dry before reinstalling.

To replace the grease filter, the metal handles

on the filter casing should be facing toward the

front of the unit.