Part No. 4801-1016 Rev 6-09

Super-Saver XL Heater – 100 Volt

Page

3 of 21

Adjustable Wrench

Gas Leak Testing Solution

Pipe Glue

1/4

″ (7 mm)

Nut Driver

Install screw hooks with hammer or drill.

HEATER DIMENSIONS

WEIGHT

130 lb. (60 kg)

HEIGHT

30 in. (76.2 cm)

WIDTH

24-1/2 in. (62.2 cm)

DEPTH

19-1/4 in. (48.9 cm)

Table Of Contents

1.

Specifications And Requirements..................4

2.

Warnings And Cautions .................................5

3.

Maintenance And Warranty ...........................6

4.

Installation......................................................7

5.

User Instructions ............................................8

6.

Component And Wiring Diagram ...................9

7.

Ladder Type Schematic Diagram ................10

8.

Servicing Instructions...................................11

9.

Pipe Sizing Guidelines.................................16

10.

Parts & Assemblies......................................18












1.

Specifications and Requirements






















MINIMUM CLEARANCES

The heater must be located a minimum of 12 inches (305 mm) from the ceiling, a minimum of 12 inches (305 mm)

from the wall on the sides and back, a minimum of 20 inches (305 mm) from the ground, and positioned such that

livestock and combustible materials are unable to come in contact with the heater or within 10 feet (3 meters) of the

hot air discharge. (See Figure 1 - Installation Instructions).

Be Sure To Check Delivery

!

Locate packing slip and make sure
all of the listed parts are enclosed.
If not, call your Hired-Hand
Distributor immediately.

Model No.

Maximum Input

Ventilation

(air required to support combustion)

HH-SS-175-XL

175,000 BTUH (36.6 kW)

1000 CFM (1699 m

3

/hr)

HH-SS-200-XL

200,000 BTUH (58.6 kW)

1000 CFM (1699 m

3

/hr)

HH-SS-225-XL

225,000 BTUH (65.9 kW)

1000 CFM (1699 m

3

/hr)

LP/Propane

Gas

Maximum 14 in. W.C. (34.8 mbar) and minimum 12.5 in. W.C. (31.1 mbar) inlet gas supply
pressure acceptable at gas regulator connection. Burner manifold pressure 11 in. W. C. (27.4
mbar) at maximum input. Gas pressure should be checked by a certified gas technician while
heater is in operation.

Natural

Gas

Maximum 14 in. W.C. (34.8 mbar) and minimum 5 in. W.C. (12.5 mbar) inlet gas supply pressure
acceptable at gas regulator connection. Burner manifold pressure of 3.5 in. W. C. (8.7 mbar) at
maximum input. Gas pressure should be checked by a certified gas technician while heater is in
operation.

Refer to heater ratings plate for unit voltage, amperage, and frequency ratings.