Hired-Hand Unitized Mega Cool: Square Bottom User Manual
Page 20

Part No. 4801-5396 Rev. 5-08
Unitized System - Square Reservoir
Page 20 of 63
Install In-Line Pump and Assemble
Supply Line – End Mount Pump
1. Place In-Line Pump on the platform as shown.
2. Connect the upper port of the strainer basket to the union. Hand
tighten ONLY.
3. Connect two 1-1/2" (3.81 cm) couplings; to the outlet side and
inlet sides of the filter. Cut two lengths of 2-1/2" (10.16 cm)
from 1-1/2" (3.8 cm) dia. PVC pipe. Install one end of pipe to
strainer basket union and the other end to the 1-1/2" (3.8 cm)
coupling on the outlet-side of the filter.
NOTE: Install filter with the arrow pointed in the direction of
water flow (toward the In-Line Pump).
4. Connect the other 2-1/2"(10.16 cm) length piece of pipe to the
inlet-side of the filter and to the ball valve.
Unitized Systems are designed to span lengths up to 80 feet from a
single water supply and pump located at the end of the System as shown
in the diagram below. If longer lengths are required, contact your area
distributor for additional information.
PVC Reducer
1 1/4"x 1 1/2"
(1021-6016)
1 1/2" Ball Valve
(1009-0101)
Pump Support Bracket
(0404-8368)
Fitting (1021-6021)
With Gasket (1028-5003)
Outlet End Cap
(0406-10079)
1 1/2" Ball Valve
(1009-0101)
PVC Elbow 1 1/2"
(1021-0106)
1 1/2” PVC Pipe:
52" long pipe for a 4 ft System
64" long pipe for a 5 ft System
76" long pipe for a 6 ft System
1 1/2" Ball Valve
(1009-0101)
5" Long pipe
2 3/8 long pipe
Pump Union
(1021-6023)
Pump
Strainer
(1062-5017)
1 1/2" Ball Valve
(1009-0101)
Male Adapter
PVC Fitting
(1021-0109)
1 1/2 Union
(1021-0110)
2 1/2" Long pipe
Strainer
(1062-5017)