Front view – Hired-Hand Unitized Mega Cool: Square Bottom User Manual
Page 9

Part No. 4801-5396 Rev. 5-08
Unitized System - Square Reservoir
Page 9 of 63
Front View
Splice
12" Between
Brackets
(Splice in Center)
Splice
L-Bracket
Flat Bottom Reservoir Support Brackets – End Pump Only
1.
Determine the height at which the bottom of the MegaCool system should be mounted above the ground. Make a
mark on each end post to represent the height.
IMPORTANT: The height of the bottom of the System should be a minimum of 9-1/2 inches above the ground in order
to elevate the pump above ground. Failure to do so may void the motor warranty.
2.
Stretch a chalk line between marks of end posts.
3.
Align bottom edge of metal support bracket with chalk line distances shown above. Use 1/4" x 1-1/2" Lag screws
for wood framing, or, #14 x 1"Hex Head TEK screws for metal framing.
4.
Assemble L-Brackets to support brackets as shown above with 1/4"-20 hex bolts and 1/4" -20 nuts.
Left
Right
Center
108 1/4"
Typ
12"
Typ
4"
Typ
58 1/4"
Typ