Variable speed wiring, Recommended wire gauge for low voltage hookup, System 1000 power vent remote fan drive unit – Hired-Hand System 1000 Power Vent User Manual
Page 23: System 1000 power vent

System 1000 Power Vent
System 1000 Power Vent
Initializing the Controller
Initializing the Controller
••
20
20
System 1000 Power Vent
Remote Fan Drive Unit
POS
CNTRL
IN
OUT
Monitor
AC HOT
CNTRL IN
Light/VAR
Monitor Alarm
Pressure
LO
L1
N.C.
Com
N.O.
Yellow
Red
BLK
12 AMP
VAR Speed
Stage 8
Stage 7
Stage 6
Stage 5
Out
In
In
In
In
In
Out
Out
Out
Out
FAN
MOTOR
2 AMP
2 AMP
2 AMP
2 AMP
HOT
AC To FAN
Terminals on
controller labeled
In
Out
Fan
Motor
Breaker Panel
Hot
120 VAC or
240 VAC
Variable Speed Wiring
When wiring the Variable speed fans, connect the "hot line" from the
breaker panel to the terminal positions marked "Variable Speed In" on the
board in the bottom of the controller. From the Out connection, run a wire to
the fan motor.
For operation with the Remote Fan Drive Unit, you will need to wire the
system as shown below.
Recommended Wire Gauge for LOW VOLTAGE hookup.
Component
HHI Wiring Part
No.
Recommended Wire
Sensor
1502-2427
18/2 Shielded Cable
Hall Effect Devices
1502-2427
18/2 Shielded Cable
PVR-H
1503-1508
18/3 Cable SJT