15. References

Program Parameters

P5 – Heater Shutoff

This setting is the shut off temperature of Stage 4
of the Farm Hand 4-ST when Stage 4 is used as a
heating option.

P6 – Mister Timer ON/OFF

This parameter turns the Mister Timer Cycle
On or Off.

P7 – Mister Timer Cycle

This parameter sets the total cycle time of the
Mister Timer (The range is from 2 min. to 30 min.)
Only seen if P6 is ON.

P41- Software Version
Number

This parameter is a software version number.
This is a read-only parameter.

P41-Setup Number

This parameter is the setup number.
This is a read-only parameter.

P51-Sensor 1
Temperature Calibration

This is the calibration temperature for Sensor 1.
Refer to Table 3 for setting instructions.

P52-Sensor 2
Temperature Calibration

This is the calibration temperature for Sensor 2.
Refer to Table 3 for setting instructions.

SWX1- Fahrenheit or Celsius

Switches the temperature readings from Fahrenheit
to Celsius. If the switch is set to ON the controller
will read the sensors as Fahrenheit.

SWX2--5/10 Minute Timer

This switch selects between a 5 and 10 minute
system cycle timer. If the switch is ON, the cycle
time is set 10 minutes.

SWX3-Heat/Cool Stage 4

Option

This switch selects the heat or cool option for stage
4. If the switch is set to the ON position, then stage
4 is programmed to control heater(s). If this switch
is set to the OFF position, then stage 4 is
programmed to control cooling.

SWX4-One/Two Sensor

Option

This switch selects the Heat or Cool Option for
stage 4. If the switch is in the ON position, then the
average temperature of Sensor 1 and Sensor 2 is
used as reference and displayed as the Room Temp.
readout. If the switch is in the OFF position, then
Sensor 1 is selected as the reference and displayed
as the Room Temp. parameter.

SWX5 115/230v Switch

This switch selects the line voltage. The voltage
positions are labeled on the switch.
IMPORTANT: THIS SWITCH MUST BE SET
TO THE CORRECT POSITION BEFORE
PLUGGING THE UNIT INTO THE POWER
SOURCE.

Farm Hand 4-ST