Operation – Lincoln Electric IM678 RED-D-ARC EX350i User Manual

Page 16

Advertising
background image

B-5

OPERATION

B-5

AUXILIARY POWER

115VAC, 42VAC and 24VAC power is available

from the two 14-pin amphenols on the rear of the
unit. These supplies are intended to supply power
for auxiliary equipment like wire feeders and the TIG
Module.

115VAC supply is rated at 2 amps and is protected

by a 2.5 amp breaker located by the amphenol.

42 VAC supply is rated at 5.5 amps and is protected

by a 6 amp breaker located by the amphenol.

24 VAC supply is rated at 5.5 amps and is protected

by a 6 amp breaker located by the amphenol.

LIMITATIONS

The EX350i is not recommended for processes

other than those listed.

The EX350i can only be used with the recommend-

ed equipment and options.

RECOMMENDED PROCESSES

Properly equipped, the EX350i supports GMAW,
FCAW, SMAW, GTAW and CAC-A processes for a
variety of materials, including mild steel, stainless
steel, cored wires, and aluminum.