Installation, Technical specifications – Lincoln Electric IM678 RED-D-ARC EX350i User Manual

Page 8

Advertising
background image

EX350i

A-1

INSTALLATION

A-1

TECHNICAL SPECIFICATIONS -

EX350i

INPUT AC VOLTAGE & DC OUTPUT

OUTPUT CABLES, CONNECTIONS AND LIMITATIONS

Product

Ordering

Input AC

Rated DC Output Output

Weight Dimensions

Name Information Voltage

Amps/Volts/Duty Cycle

Range

with Cord

HxWxD

(continuous)

200

Factory

208-230/

350A / 34V / 60%

82.5lbs

380-400/

AMPS

(37.4 kg) 14.7”x12.5”x27.8”*

EX350i

K1757-1

415-460/

5-425

Construction

575

81.5lbs

(373x318x706*)mm

1 & 3 Phase

275A / 31V / 100%

(36.9 kg)

60/50 Hz

* Overall Length Including Handle, 27.8” (706mm).

Select the output cable size based upon the following chart.
Cable sizes for Combined Length of Electrode and Work Cable (Copper) 75C rated:

DUTY CYCLE

CURRENT

LENGTH UP 61m (200 FT)

61-76m (200-250 FT)

100%

275

1/0

1/0

60%

350

1/0

2/0

EX350i INPUT CURRENT

Note 2. When operating on these inputs, the line cord should be changed to an input conductor of 6 AWG or larger.

Recommended Fuse Sizes Based On The U.S. National Electrical Code And Maximum Machine Outputs

Input 50/60 Hz

Output

Recommended

Voltage

Phases

275Amps@

350Amps@

Line Cord

Size Fuse Size Notes

31Volts(100%)

34Volts(60%)

AWG[IEC] SIZES

200

1

Not

Not ---

---

Note 1

Recommended Recommended

208

1

70

94

2

125A

Note 2

230

1

62

85

4

125A

Note 2

380

1

Not

Not ---

---

Note 1

Recommended Recommended

400

1

Not

Not

---

---

Note 1

Recommended Recommended

415

1

38

54

6

80A

Note 2

460

1

34

42

8

70A

575

1

27

37

8

50A

200

3

37

50

8

80A

Note 2

208

3

36

50

6

80A

Note 2

230

3

31

42

8

70A

380

3

21

28

8

50A

400

3

20

27

8

50A

415

3

19

26

8

50A

460

3

17

23

8

50A

575

3

14

18

8

35A

Note 1. Not rated is indicated by 4-x's in the box on the rating plate.

Advertising