Troubleshooting, Caution – Lincoln Electric IM678 RED-D-ARC EX350i User Manual

Page 20

Advertising
background image

EX350

i

E-2

TROUBLESHOOTING

E-2

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your

Local Authorized Field Service Facility

for technical troubleshooting assistance before you proceed.

CAUTION

Observe all Safety Guidelines detailed throughout this manual

PROBLEMS

(SYMPTOMS)

POSSIBLE AREAS OF

MISADJUSTMENT(S)

RECOMMENDED

COURSE OF ACTION

Major physical or electrical damage
is evident when the sheet metal cov-
ers are removed.

Input fuses keep blowing, or input
breaker keeps tripping

Machine will not power up (No lights)

Machine won

t weld, can

t get any

output.

1. Contact your local authorized

Field Service facility for technical
assistance.

1. Make certain that the fuses or

breakers are properly sized. See
installation section of the manual
for recommended fuse and break-
er sizes.

2. Welding procedure is drawing too

much output current, or duty cycle
is too high. Reduce output cur-
rent, duty cycle or both.

3. There is internal damage to the

power source. Contact an autho-
rized Lincoln Electric Service facil-
ity.

1. Make certain that the power

switch is in the "ON" position.

2. The circuit breaker in the recon-

nect area may have opened.
Reset. Check input voltage sec-
tion below.

3. Input voltage selection made

improperly. Power down, check
input voltage reconnect according
to diagram on reconnect cover.

1. If the displays show an Err ###

see the fault section for corrective
action.

2. If the displays are not lit refer to

machine will not power up section.

3. If the thermal symbol is lit refer to

the thermal section.

4. If the output terminals are in

Remote control switch to "ON"
and check for output voltage. If
output voltage is now present
check for correct remote control
connection and operation.

If all recommended possible areas
of misadjustment have been
checked and the problem persists,

Contact your local Authorized
Field Service Facility.

Advertising