Operation, Controls and settings, Invertec v250-s – Lincoln Electric IM589 INVERTEC V250-S User Manual

Page 13

Advertising
background image

B-2

OPERATION

B-2

1. Power Switch - Place the lever in the “ON” position to

energize the machine. When the power is on, the fan will
operate and the output will be energized in SMAW
modes. GTAW mode requires remote trigger to energize
the output.

2. Output Control - This controls the output current. Control

is provided over the entire output range of the power
source with 1 turn of the control knob. This control may
be adjusted while under load to change power source
output. When using remote control this function becomes
the limit setting.

3. Local/Remote Switch - Place in the “LOCAL” position to

allow output adjustment at the machine. Place in the
“REMOTE” position to allow output adjustment at remote
pot or amptrol. In Remote, the machine output control pot
is the limit setting for remote control.

4. Mode Switch

GTAW

Optimized for touch start use. Triggering at

amphenol is required using an Arc Start Switch, Amptrol
or similar means. Short circuit current is limited to approx-
imately 25 amps to aid in touch starting.

CC Soft

Best for EXX18 thru EXX28 stick electrodes.

Output energized when machine is on.

CC Crisp

Use this mode for stick welding with EXX10

thru EXX14 electrodes. Output energized when machine
is on.

5. Hot Start - Controls the amount of starting energy in

SMAW. The Hot Start setting will set the amount of extra
power given during the initial strike.

A Hot Start setting of 100% will give you an additional
striking current 100% above the welding set current*.
(Striking current in this example will be 200% of the set
current). For a Hot Start setting of 100%, the current will
decrease back to the set current in one second.

A Hot Start setting of 50% will give you an additional
striking current 50% above the welding set current*.
(Striking current in this example will be 150% of the set
current). For a Hot Start setting of 50%, the current will
decrease back to the set current in .5 second.

* The maximum striking current is 300 Amps.

INVERTEC V250-S

CONTROLS AND SETTINGS

All operator controls and adjustments are located on the case front of the V250-S. Refer to Figure B.1 and corre-
sponding explanations.

FIGURE B.1 — CASE FRONT CONTROLS.

O

I

INVERTEC V250-S

®

S

-

+

1

15

50

85

120

170

230

250

A

OUTPUT

SMAW

SOFT

GTAW

SMAW

CRISP

REMOTE

LOCAL

THERMAL

HOT START

1

2

3

4

6

7

8

9

10

5

0

ARC FORCE

1

2

3

4

6

7

8

9

10

5

0

1

2

3

4

5

6

7

8

Advertising