Installation – Lincoln Electric IM589 INVERTEC V250-S User Manual
Page 8
A-1
INSTALLATION
INVERTEC V250-S
A-1
Height
Width
Depth
Weight
15.0 in.
9.1 in.
19.7 in.
36.5 lbs.
381 mm
231 mm
500 mm
16.6 Kg
PHYSICAL DIMENSIONS
THREE PHASE
Standard
Input Current
Voltage at Rated Output Model
380-415 20-18
50/60
Hz
Volts at
Duty Cycle
(1)
Amps
Rated Amps Model
35% Duty Cycle
250
30
50/60Hz
60% Duty Cycle
200
28
50/60Hz
100% Duty Cycle
165
26
50/60Hz
Welding
Constant Open
Current Range
Circuit Voltage
1-250 Amps
60-75 VDC
INPUT
RECOMMENDED INPUT WIRE AND FUSE SIZES
Type 75°C
Type 75°C
Copper
Fuse
Input
Copper
Ground
(Superlag)
Ampere
Wire in
Wire in
Input
or
Rating
Conduit
Conduit
Voltage
Breaker
on
AWG (IEC)
AWG (IEC)
Frequency
(2)
Size
Nameplate
Sizes
Sizes
380-415/50/60
35
20-18
12 (4mm
2
)
12 (4mm
2
)
THREE PHASE
THREE PHASE
THREE PHASE
OUTPUT
RATED OUTPUT
(1) Based on a 10 min. period.
(2) Input voltage must be within ±10% of rated value.
Technical Specifications - Invertec V250-S (380-415 VAC Model)