Operation, B-16 – Lincoln Electric IM761 POWER FEED 15M User Manual

Page 30

Advertising
background image

WELD:

After upslope, the power source output and the wire
feed speed continue at the weld settings.

CRATER:

As soon as the trigger is released, the wire feed
speed and power source output ramp to the crater
settings throughout the crater time. The time period of
ramping from the weld settings to the crater settings is
called DOWNSLOPE.

BURNBACK:

After the crater time expires, the wire feed speed is
turned OFF and the machine output continues for the
burnback time.

POSTFLOW:

Next, the machine output is turned OFF and shielding
gas continues until the post flow timer expires.

B-16

OPERATION

B-16

POWER FEED 15M

Shielding
Gas

Idle

Preflow

Stri ke

U pslo pe

Weld

Bu rnba ck

Postflow

Idl e

WFS

On

Off

Run -in

Off

We ld

Off

We ld

Arc Established

T

rigger Pulled

T

rigger Released

2 St ep Trig ger
St art = ON
C rater = ON
B urnback = ON

1.5 sec max .

Start

St art t ime

B urnback Time

Do wn slop e

Crate r

Crater ti me

Po wer
So urce
Output

C rater

FIGURE B.8

EXAMPLE 3 - 2 STEP TRIGGER:

Customize Arc

Start, Crater and Arc End. Sometimes it is advanta-
geous to set specific arc start, crater and arc ending
parameters for the ideal weld. Many times when
welding aluminum crater control is necessary to make
a good weld. This is done by setting Start, Crater
and Burnback functions to desired values. (See
Figure B.8)

For this sequence,

PREFLOW:

Shielding gas begins to flow immediately when the
gun trigger is pulled.

STRIKE:

After preflow time expires, the power source regulates
to the start output and wire is advanced towards the
work piece at the Strike WFS. If an arc is not estab-
lished within 1.5 seconds, the power source output
and wire feed speed skips to the weld settings.

UPSLOPE:

Once the wire touches the work and an arc is estab-
lished, both the machine output and the wire feed
speed ramp to the weld settings throughout the start
time. The time period of ramping from the start set-
tings to the weld settings is called UPSLOPE.

Advertising