POWER FEED 15M

E-2

TROUBLESHOOTING

E-2

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your

Local Lincoln Authorized Field Service Facility

for technical troubleshooting assistance before you proceed.

CAUTION

Fault Code

Err 006

Err 100

Err 31 Primary overcurrent.

Err 32 Capacitor bank "A"

under voltage.

Err 33 Capacitor bank "B"

under voltage.

Err 34 Capacitor bank "A"

overvoltage.

Err 35 Capacitor bank "B"

overvoltage.

Err 41 Long term secondary

overcurrent.

Description

1. The wire feeder has not received

a recognition command from the
power source. The power source
has issued a shutdown command.

1. The power source has issued a

shutdown command.

1. The power source has exceeded

input current limits.

2. See the power source Instruction

Manual.

1. The power source input power

may be wired incorrectly.

1. The power source input power

may be wired incorrectly.

1. The power source input power

may be wired incorrectly.

1. The power source input power

may be wired incorrectly.

1. The power source has exceeded

the output current limits.

2. See the power source Instruction

Manual.

Possible Adjustments

1. Verify the power source is operat-

ing properly (Status light steady
green.)

2. Check control cable for loose or

broken leads.

3. See power source Instruction

Manual.

1. Verify the power source is operat-

ing properly (Status light steady
green.)

2. Check control cable for loose or

broken leads.

3. See power source instruction

Manual.

1. Adjust the welding procedure to

reduce the current draw. The
welding procedure may exceed
the capacity of the power source.

1. Verify the power source reconnect

panel wiring matches the input
power.

2. See the power source Instruction

Manual.

1. Verify the power source reconnect

panel wiring matches the input
power.

2. See the power source Instruction

Manual.

1. Verify the power source reconnect

panel wiring matches the input
power.

2. See the power source Instruction

Manual.

1. Verify the power source reconnect

panel wiring matches the input
power.

2. See the power source Instruction

Manual.

1. Adjust the welding procedure to

reduce the current draw. The
welding procedure may exceed
the capacity of the power source.

Observe all Safety Guidelines detailed throughout this manual

PROBLEMS

(SYMPTOMS)

POSSIBLE AREAS OF

MISADJUSTMENTS

RECOMMENDED

COURSE OF ACTION

Linc-Net System Error Codes

ArcLink System Error Codes