MAINTENANCE

D-1

POWER FEED 15M

ELECTRIC SHOCK can kill.

• Do not operate with covers

removed.

• Turn off power source before

installing or servicing.

• Do not touch electrically hot

parts.

• Turn the input power to the welding power

source off at the fuse box before working in the
terminal strip.

• Only qualified personnel should install, use or

service this equipment.

WARNING

SAFETY PRECAUTIONS

ROUTINE MAINTENANCE

Check weld cables, control cables and gas hoses

for cuts.

Clean and tighten all weld terminals.

PERIODIC MAINTENANCE

Clean drive rolls and inner wire guide and replace if

worn.

Blow out or vacuum the inside of the feeder.

CALIBRATION SPECIFICATION

All calibrations are factory set on the Power Feed 15M.

To verify the wire feed speed:

Assemble a .045 (1.2mm) drive roll kit into the

Power Feed 15M.

Load a spool of .045 (1.2mm) electrode and thread

the electrode through the wire drive.

Adjust the wire feed speed to 300 in/min

(7.62m/min).

Press the COLD INCH switch and measure the

actual wire feed speed with a calibrated wire feed
speed tachometer.

The measured wire feed speed should be within 2%

of the set value.

To verify the voltage display:

Set the welding power source and Power Feed 15M

to a CV procedure that gives steady "spray" transfer
in the arc.

While a weld is being made, measure the voltage

from the feedplate to work with a calibrated volt
meter.

The displayed voltage on the Power Feed 15M

should be within 2% of the measured value.