Installation, Technical specifications - power wave – Lincoln Electric IM713 POWER WAVE 655R User Manual

Page 8

Advertising
background image

A-1

INSTALLATION

POWER WAVE

®

655/R

A-1

TECHNICAL SPECIFICATIONS - Power Wave

®

655/r (K1519-1, K1519-2)

OUTPUT

RECOMMENDED INPUT WIRE AND FUSE SIZES

PHYSICAL DIMENSIONS

TEMPERATURE RANGES

INPUT AT RATED OUTPUT - THREE PHASE ONLY

INPUT VOLTS

460/575V - 60HZ.

400V - 50HZ.

460/575V - 60HZ.

CODE NUMBERS

10630

10863

11410

11880

OPEN

CIRCUIT

VOLTAGE

75 VDC

INPUT

VOLTAGE /

FREQUENCY

460V - 60HZ.
575V - 60HZ.

HEIGHT

26.10 in

663 mm

WIDTH

19.86 in

505 mm

DEPTH

32.88 in

835 mm

WEIGHT

306 lbs.

139 kg.

TYPE 75°C

(SUPER LAG)

OR BREAKER

SIZE (AMPS)

70
60

TYPE 75°C

GROUND WIRE IN

CONDUIT AWG[MM

2

]

SIZES

8 (10)
10 (6)

TYPE 75°C

COPPER WIRE IN

CONDUIT AWG[MM

2

]

SIZES

6 (16)

6(16)

PROCESS CURRENT RANGES (DC)

MIG/MAG

FCAW

SMAW

Pulse

CURRENT

50-815 Average Amps
40-815 Average Amps
30-600 Average Amps

15-880 Peak Amps

PULSE

VOLTAGE

RANGE

5 - 55 VDC

AUXILIARY POWER

(CIRCUIT BREAKER

PROTECTED)

40 VDC AT

10 AMPS

110 VAC AT

10 AMPS

PULSE AND

BACKGROUND

TIME RANGE

100 MICRO SEC. -

3.3 SEC.

CURRENT

RANGE

20-815

PULSE

FREQUENCY

0.15 - 1000 Hz

INPUT

CURRENT

AMPS

43/34
53/42

40
51

41/33
53/42

IDLE

POWER

400 Watts

Max.

POWER FACTOR

@ RATED OUT-

PUT

.95 MIN.

EFFICIENCY

@ RATED

OUTPUT

84%

OUTPUT

CONDITIONS

[email protected]%

815A@44V. 60%

[email protected]%

675A@44V. 60%

[email protected]%

815A@44V. 60%

OPERATING TEMPERATURE RANGE

-20°C to +40°C

STORAGE TEMPERATURE RANGE

-40°C to +40°C

Advertising