Installation, Technical specifications – Lincoln Electric IM943 POWER WAVE i400 User Manual

Page 10

Advertising
background image

A-1

INSTALLATION

POWER WAVE

®

i400

A-1

TECHNICAL SPECIFICATIONS -

POWER WAVE

®

i400 (K2669-1, K2673-1)

RATED OUTPUT

RECOMMENDED INPUT WIRE AND FUSE SIZES

1

PHYSICAL DIMENSIONS

TEMPERATURE RANGES

INPUT AT RATED OUTPUT - THREE PHASE ONLY

Model

K2669-1

K2673-1

(Chassis Only)

Duty Cycle

40% rating

60% rating

100% rating

3 PHASE INPUT

VOLTAGE

50/60Hz

208
230
380
460
575

Input

Amperes

(incl. robot and

aux. load)

54 (73)
49 (66)
28 (38)
25 (33)
20 (26)

HEIGHT

22.7 in. (577 mm)

21.0 in. (533 mm)

MODEL

K2669-1

K2673-1

WIDTH

24.4 in. (620 mm)

22.6 in. (574 mm)

DEPTH

21.5 in. (546 mm)

18.5 in. (470 mm)

WEIGHT

209 lbs. (95 kg.)

147 lbs. (66.8 kg.)

Fuse (Super Lag) or

Breaker Size

2

80
70
50
40
30

COPPER GROUNDING

CONDUCTOR

AWG (mm

2

)

8 (10)
8 (10)
10 (6)
10 (6)
10 (6)

Type 75°C Copper

Wire in Conduit

AWG (mm

2

)

4 (25)
4 (25)
8 (10)
8 (10)
10 (6)

Volts at Rated Amperes

35

34

31.5

Amperes

420

400

350

Duty Cycle

40%

60%

100%

Process

GMAW

GMAW-Pulse

FCAW

GTAW-DC

Input Amperes

(incl. robot and

aux. load)

54/49/28/25/20

(73/66/38/33/26)

50/45/26/23/18

(69/62/36/31/25)

40/37/21/18/15

(59/54/31/27/21)

Idle Power

475 Watts

Max.

(fan on)

Power Factor @

Rated Output

.95

Input Voltage ± 10%

208†/230/380*/460/575

3 phase 50/60 Hz

(

† includes 200V to 208V)

(* includes 380V to 415V)

OPERATING TEMPERATURE RANGE

14°F to 104°F (-10°C to 40°C)

STORAGE TEMPERATURE RANGE

-40°F to 185°F(-40°C to 85°C)

1 Wire and Fuse Sizes based upon the U.S. National Electric Code and maximum output for 40°C (104°) ambient.
2 Also called “inverse time” or “thermal/magnetic” circuit breakers; circuit breakers that have a delay in tripping action that decreases as the

magnitude of current increases.

Advertising