Specifications – Lincoln Electric IM491 PRO-CUT 125 User Manual

Page 7

Advertising
background image

– 7 –

SPECIFICATIONS

Type

K1394-* and K1395-*
K880-1[25Ft.(7.6m)Cable] & K880-2 [50Ft.(15.2m)Cable]
Magnum PCT125 Air Cooled Torch

Input Frequency

50 or 60 Hz, 3ø

Output Rating

125 Amps, 148 volts, 60% Duty Cycle
110 Amps, 140 volts, 80% Duty Cycle
100 Amps, 135 volts, 100% Duty Cycle

Pilot Current

26 amps

Pilot Duty Cycle

25% (20 seconds out of 80 seconds)

Current Range

50-125 Amps

Maximum OCV

@10% High Input

357

Normal OCV

325

Input Power

Standard Voltages

230/460/3/50/60

220/380/440/3/50/60

575/3/60

Current

101/49 @ 60%

102/59/51 @ 60%

40 @ 60%

95/44 @ 80%

87/54/45 @ 80%

33 @ 80%

88/40 @ 100%

81/49/42 @ 100%

32 @ 100%

Idle Current

4.5 amps @ 220V

Idle Power

0.7 kW Maximum

Power Factor @ Rated Load

0.60

Net Weight

w/25 ft. (7.6 m) Cable

480 lbs/218.2 kg

w/50 ft. (15.2 m) Cable

489 lbs/222.3 kg

Dimensions, H x W x D

35.6” x 19” x 22” (905mm x 483mm x 559mm)

(includes lift bail and undercarriage)

* Several standard input voltages and options packages are available specified by type number.

Advertising