SPECIFICATIONS
Type
K1394-* and K1395-*
K880-1[25Ft.(7.6m)Cable] & K880-2 [50Ft.(15.2m)Cable]
Magnum PCT125 Air Cooled Torch
Input Frequency
50 or 60 Hz, 3ø
Output Rating
125 Amps, 148 volts, 60% Duty Cycle
110 Amps, 140 volts, 80% Duty Cycle
100 Amps, 135 volts, 100% Duty Cycle
Pilot Current
26 amps
Pilot Duty Cycle
25% (20 seconds out of 80 seconds)
Current Range
50-125 Amps
Maximum OCV
@10% High Input
357
Normal OCV
325
Input Power
Standard Voltages
230/460/3/50/60
220/380/440/3/50/60
575/3/60
Current
101/49 @ 60%
102/59/51 @ 60%
40 @ 60%
95/44 @ 80%
87/54/45 @ 80%
33 @ 80%
88/40 @ 100%
81/49/42 @ 100%
32 @ 100%
Idle Current
4.5 amps @ 220V
Idle Power
0.7 kW Maximum
Power Factor @ Rated Load
0.60
Net Weight
w/25 ft. (7.6 m) Cable
480 lbs/218.2 kg
w/50 ft. (15.2 m) Cable
489 lbs/222.3 kg
Dimensions, H x W x D
35.6” x 19” x 22” (905mm x 483mm x 559mm)
(includes lift bail and undercarriage)
* Several standard input voltages and options packages are available specified by type number.