INSTALLATION

SP-100T

A-6

INPUT CONNECTIONS

Refer to Figure A.6.

The SP-100T has a power input cable located on the
rear of the machine.

FIGURE A.6

CODE REQUIREMENTS FOR INPUT
CONNECTIONS

This welding machine must be connected to a
power source in accordance with applicable elec-
trical codes.

The United States National Electrical Code (Article
630-B, 1990 Edition) provides standards for
amperage handling capability of supply conduc-
tors based on duty cycle of the welding source.

If there is any question about the installation
meeting applicable electrical code requirements,
consult a qualified electrician.

Requirements For Rated Output

A power cord with a 15 amp, 125 volt, three prong
plug (NEMA Type 5-15P) is factory installed on the
SP-100T. Connect this plug to a mating grounded
receptacle which is connected to a 20 amp branch cir-
cuit with a nominal voltage rating of 115 to 125 volts,
60 Hertz, AC only.

The rated output with this installation is 88 amps, 18
Volts, 20% duty cycle (2 minutes of every 10 minutes
used for welding).

Do not connect the SP-100T to an input power
supply with a rated voltage that is greater than 125
volts.

Do not remove the power cord ground prong.

Requirements For CSA Rated Output

A line cord with a 15 amp, 125 volt, three-prong plug
(NEMA Type 5-15P) is factory installed. Connect this
plug to a mating grounded receptacle which is con-
nected to a 15 amp branch circuit with a nominal volt-
age rating of 115 volts to 125 volts, 60 hertz, AC only.
With this installation, the SP-100T can be used at an
output of 62 amps, 20 volts, 20% duty cycle.

POWER INPUT
CABLE

GAS SOLENOID
INLET FITTING

WARNING

CAUTION