Troubleshooting, Caution, Troubleshooting guide – Lincoln Electric IM564 SP-100T User Manual

Page 40

Advertising
background image

E-2

TROUBLESHOOTING

E-2

SP-100T

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your

Local Lincoln Authorized Field Service Facility

for technical troubleshooting assistance before you proceed.

CAUTION

Observe Safety Guidelines

detailed in the beginning of this manual.

TROUBLESHOOTING GUIDE

PROBLEMS
(SYMPTOMS)

Major physical or electrical damage
is evident.

No wire feed, weld output or gas
flow when gun trigger is pulled. Fan
does NOT operate.

No wire feed, weld output or gas
flow when gun trigger is pulled Fan
operates normally.

POSSIBLE AREAS OF
MISADJUSTMENT(S)

None
Contact your local Authorized Field
Service Facility.

1. Make sure correct voltage is

applied to the machine (115vac).

2. Make certain that power switch

is in the ON position.

3. Make sure circuit breaker inside

wire drive compartment is reset.

1. The thermostat may be tripped

due to overheating. Let machine
cool. Weld at lower duty cycle.

2. Check for obstructions in air

flow. Check Gun Trigger connec-
tions. See Installation section.

3. Gun trigger may be faulty.

RECOMMENDED
COURSE OF ACTION

Contact your local Lincoln
Authorized Field Service Facility.

OUTPUT PROBLEMS