Accessories – Lincoln Electric IM724 SP-135T User Manual

Page 33

Advertising
background image

C-2

ACCESSORIES

C-2

INNERSHIELD (FCAW)
CONVERSION

Several changes are needed to convert the unit for
operation with the Innershield (FCAW) process. The
K549-1 or K549-2 Innershield Kits include all the nec-
essary accessories for this conversion and are provid-
ed for this purpose. The following conversions should
be made using the contents of this kit:

1. Change the output polarity to DC(–). See “Work

Cable Installation” in Installation section for details.

2. Install proper drive roll for the wire size selected.

See “Changing Drive Roll” in Maintenance section
for details.

3. Install the proper gun liner and tip for the wire size

selected. See “Component Replacement” in
Maintenance section for details.

4. Remove gas nozzle (if installed) and install gasless

nozzle. To remove, simply unscrew.

5. Load wire into machine and thread into gun and

cable per “Welding Wire Loading” section.

REPLACEMENT PARTS

Complete Gun and Cable Assembly

L8311-6 (K530-4)

Contact Tip .025

(0.6 mm)

S19726-1

Contact Tip .030

(0.8 mm)

S19726-2

Contact Tip .035

(0.9 mm)

S19726-3

Contact Tip-Tapered .025

(0.6 mm)

S20278-1

Contact Tip-Tapered .030

(0.8 mm)

S20278-2

Contact Tip-Tapered .035

(0.9 mm)

S20278-3

Liner .023 - .030

(0.6 - 0.8 mm)

M16291-2

Liner .030 - .035

(0.8 - 0.9 mm)

M16291-6

Liner .035/.045

(0.9/1.2 mm)

M16291-1

Gas Diffuser

S19728

Gas Nozzle

M16294

Gas Nozzle-Tip Recessed 3/8

(9.5 mm)

Opening I.D.

M16684

Gas Nozzle-Tip Recessed 1/2

(12.7 mm)

Opening I.D.

M16684-1

Gas Nozzle-Tip Recessed 5/8

(15.9 mm)

Opening I.D.

M16684-2

Spot Welding Nozzle

M17846

Gasless Nozzle (Innershield Only)

M16418

SP-135T

Advertising