A-4

A-4

INSTALLATION

Work Cable Installation

Refer to Figure A.2.

1. Open the wire feed section door on the right side of

the SP-170T.

2. Pass the end of the work cable that has the termi-

nal lug with the smaller hole through the Work
Cable Access Hole (1) in the case front.

3. Route the cable under and around the back of the

Wire Feed Gearbox (6).

4. For GMAW Only: Refer to Figure A.2. As deliv-

ered, the machine is connected for positive elec-
trode polarity. This is the appropriate configuration
for the GMAW (MIG) process. To complete installa-
tion, use the provided wing nut to connect the work
cable’s terminal lug to the negative (–) output ter-
minal (5) located above the Wire Feed Gearbox
(6). Make sure that both wing nuts are tight.

5. For Innershield Only: Refer to Figure A.4. To wire

for negative polarity (required for the Innershield
process), connect the short cable attached to the
connector block (1) to the negative (–) output termi-
nal (2) and the work cable (3) to the positive (+) ter-
minal (4).

FIGURE A.4

NOTE: If .035" or .045" (0.9 mm or 1.2 mm)
Innershield flux-cored wire is to be used, the appropri-
ate Innershield kit is required.

Connecting Gun Cable to the SP-170T

1. Refer to Figure A.2. Unplug the machine or turn

power switch to the OFF “O” position.

2. Pass the insulated terminals of the gun trigger con-

trol leads, one at a time, through the Gun Cable
and Control Lead Access Slot (2) in the case front.
The leads are to be routed up the inside of the
case front, behind the gas line.

3. Insert the connector on the gun conductor cable

through the Gun Cable Access Hole (2) in the
SP-170T case front. Make sure the connector is all
the way in the brass connector block to obtain
proper gas flow. If the gun connector will not fully
insert, unscrew the thumbscrew on the connector
block a few turns. Rotate the connector so control
leads are on the underside and tighten the
Thumbscrew on the connector block.

4. Connect the gun trigger control lead terminals to

the two insulated 1/4" (6,4 mm) tab terminal con-
nector bushings located above the “Gun Trigger
Connection” decal in the wire feed section (4).
Either lead can go to either connector.

If the gun trigger switch being used is other than
that supplied, the switch must be a normally open,
momentary switch. The terminals of the switch
must be insulated from the welding circuit.
Malfunction of the SP-170T may result if this
switch shorts to the SP-170T welding output cir-
cuit or is common to any electrical circuit other
than the SP-170T trigger circuit.

GAS CONNECTION

The SP-170T is supplied with a mixed gas Regulator
and a 3m gas hose. A cylinder of an appropriate
shielding gas must be obtained from your gas distribu-
tor.

CAUTION

GUN INSTALLATION

As shipped from the factory, the SP-170T gun is ready
to feed .023" – .025"(.6mm) solid wire. If .030" (0.8
mm) solid wire is to be used, change the contact tip to
the appropriate size.

2

4

3

1

SP-170T