TROUBLESHOOTING GUIDE

PROBLEMS
(SYMPTOMS)

Major physical or electrical damage
is evident.

No wire feed, weld output or gas
flow when gun trigger is pulled. Fan
does NOT operate.

No wire feed, weld output or gas
flow when gun trigger is pulled Fan
operates normally.

POSSIBLE AREAS OF
MISADJUSTMENT(S)

None
Contact your local Authorized Field
Service Facility.

1. Make sure correct voltage is

applied to the machine. See
Installation section, “Electrical
Connections”.

2. Make certain that power switch

is in the ON position.

3. Make sure circuit breaker inside

wire drive compartment is reset.

1. The thermostat may be tripped

due to overheating. Let machine
cool. Weld at lower duty cycle.

2. Check for obstructions in air

flow.

3. Check Gun Trigger connections.

See Installation section.

4. Gun trigger may be faulty.

RECOMMENDED
COURSE OF ACTION

If all recommended possible areas
of misadjustment have been
checked and the problem persists,
Contact your local Lincoln
Authorized Field Service
Facility.