D-2

MAINTENANCE

D-2

Use 4-stroke motor oil that meets or exceeds the
requirements for API service classification SG or SH.
Always check the API SERVICE label on the oil con-
tainer to be sure it includes the letters SG or SH.

SAE 10W-30 is recommended for general, all-temper-
ature use, -5 F to 104 F (-20 C to 40 C).

See Engine Owner

s Manual for more specific infor-

mation on oil viscosity recommendations.

Wash your hands with soap and water after handling
used oil.

Please dispose of used motor oil in a manner that is
compatible with the environment. We suggest you
take it in a sealed container to your local service sta-
tion or recycling center for reclamation.

Do not throw it in the trash, pour it on the ground or
down a drain.

OIL FILTER CHANGE

1. Drain the engine oil.

Remove the oil filter, and drain the oil into a suitable

container. Discard the used oil filter.

Clean the filter mounting base, and coat the gasket
of the new oil filter with clean engine oil.

Screw on the new oil filter by hand, until the gasket
contacts the filter mounting base, then use an oil fil-
ter socket tool to tighten the filter an additional 1/2 to
7/8 turn.

Refill the crankcase with the specified amount of the

recommended oil. Reinstall the oil filler cap.

Start the engine and check for oil filter leaks.

Stop the engine, and check the oil level. If neces-

sary, add oil to the upper limit mark on the dipstick.

Air Cleaner - With normal operating conditions, the

maintenance schedule for cleaning and re-oiling the
foam pre-filter is every 25 hours and replacement of
the air cleaner filter every 100 hours. More fre-
quent servicing is required with dusty operating
conditions. Refer to the maintenance section of the
Engine Owner

s Manual for more information.

Refer to the maintenance section of the Engine

Owner

s Manual for the maintenance schedule,

spark plug servicing, cooling system servicing, and
fuel filter replacement.

Blow out the machine with low pressure air period-

ically. In particularly dirty locations, this may be
required once a week.

Output Selector and Polarity Switch contacts

should not be greased. To keep contacts clean,
rotate the switch through its entire range frequently.
A good practice is to turn the handle from maximum
to minimum setting twice each morning before
starting to weld.

RANGER 8